3.11 ADC
The ADC value can be read by the specific AT command as defined in the document referenced [2]. The input
limits are the following: from 0V up to 1750mV
The returned value is on 10 bits converted to decimal.
3.12 Micro-wire Bus
The microwire bus is available but the client has to ask SAGEM to develop the driver and the specific
application related the connected device.
3.13 Antenna detection
Antenna detection can be provided if following criteria are met :
• Antenna design is performed according to design given below.
• Feature is activated through AT command.
AT command answer can be synchronous or asynchronous depending on customer request, as described in
AT command document referenced [ 2 ].
L
MO300
Antenna contacts
A coil L of 39µH must be added inside the
antenna connector.
Antenna
Antenna connector
50Ω track