System Description

System Description and Installation Manual for MXS ICD10004-01
© Sagetech Corporation 2018 Confidential Proprietary Export-Controlled Page 151 of 160
Step Message Msg
Direction
Field Name
18
Data Values (Hex) Data/Functional Description SDIM
System State [08] The System State byte will continue to show GPS Data, and Extended
Squitter errors until the Host Computer provides Operating and GPS
Data Messages
Pressure Altitude [00 02 77] Pressure altitude is 631 feet
Checksum [B7]
3
Receive and decode Flight ID Response Message
Flight ID
Response
Received
by host
Start Byte [AA] 14.46.4.4
Mess Type [82]
Mess ID [05]
Packet Len [0C]
Flight ID [4E 32 35 36 37 47 41 20] Flight ID was stored correctly. Flight ID = N2567GA
Reserved [00 00 00 00]
Checksum [07]
4
Construct and send Operating Message (Continue to construct and send Operating Message at 1-5 Hz )
Operating Sent from
host
Start Byte [AA] 13.46.3.4
Mess Type [03] Establishes MXS Operating Mode.
This message must be sent periodically (between 1 to 5 Hz) to
maintain Operating mode
Mess ID [06]
Packet Len [0C]