System Description

System Description and Installation Manual for MXS ICD10004-01
© Sagetech Corporation 2018 Confidential Proprietary Export-Controlled Page 28 of 160
Reserved
Byte Offset
Byte Name Field Description
10
RE0 This field is reserved for future use. Set to ZERO. All other values are invalid.
11
RE1
COM Port 0
Byte Offset
Byte Name Field Description
12
C00
Byte CO0
0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
0x08-0xFF
Com Port 0 Settings
38400 Bits per Second (Default)
600 Bits per Second
4800 Bits per Second
9600 Bits per Second
28800 Bits per Second
57600 Bits per Second
115200 Bits per Second
230400 Bits per Second
Reserved
If a baud rate change is requested of the same port that the Installation Message was received on, the
change will be postponed until the ‘acknowledge’ has been sent. The baud rate change will be
immediate for the port not used to receive the Installation Message.