System State Byte
Byte Offset
Byte Name Field Description
02
SSB0
SSB0 System State Byte indicates current Transponder State Information
Bit 0 Transponder Fail Flag
1 = an error within the Transponder. The Status message can be queried to
determine the cause of the Transponder error.
Bit 1 System Fail Flag
1 = an error detected by the transponder in which a required input from the
system is not available. The Status message can be queried to determine the
cause of the system failure.
Bit 2 Reserved
Bit 3 Weight on Wheels
1 = Transponder has detected that the WoW discrete input is valid in the
Installation message and the discrete is true indicating that the aircraft weight
is on the wheels.
Bit 4 Maintenance Mode
1= ON
Bit 5 Altitude Source
0 = Integral
1 = From host
Bits 6 - 7 Transponder Operational Mode
00 = STBY
01 = ON
11 = ALT