Use and Care Guide

Sakrete.com • 866-725-7383
The Pro’s Choice Since 1936
Surface Bonding Cement
• Installations must follow local building code requirements for block wall
installations.
Expansion joints must be specified and incorporated into the block wall
construction as specified and or by following the local building code
requirements.
Exsiting Masonry Walls:
1. Air, Mix and substrate temperatures should be a minimum of 40°F (4°C) and
remain above freezing for 24 hours.
2. Clean area and remove all unsound concrete, grease, oil, paint,
efflorescence, and any other foreign materials that will inhibit performance.
3. Slick and sealed surfaces must be thoroughly roughened.
4. If cracks exist, chip out and enlarge to approximately ½ inch deep and repair
using Sakrete Surface Bonding Cement prior to coating the entire wall.
5. Apply Sakrete Surface Bonding Cement only after repairs are made and
substrate is restored to a sound condition.
6. Dampen surface before applying Surface Bonding Cement.
Dry Stack Walls:
When Surface Bonding Cement is applied to both sides of a block wall the
strength is considerably stronger than when building a traditional mortared
joint wall. This technique is best used when building a dividing wall or any wall
that will not contain doors or windows. The spacing for almost all traditional
walls requires a 3/8” (10 mm) mortar joint. If Surface Bonding Cement is used
in a structural application, consult local building codes. Air, Mix and substrate
temperatures should be a minimum of 40°F (4°C) and remain above freezing for
24 hours.
1. When laying a new block wall first construct a sound footing below the
frost line.
2. Level the first course of block in a full bed of mortar.
3. Stack the remaining courses of block without mortar from corners in a
running bond pattern.
4. Butt the blocks together.
5. Use galvanized brick ties as shims when necessary for leveling while
stacking.
6. Fill gaps larger than 1/4” (6 mm) with Sakrete Surface Bonding Cement
prior to coating the wall.
7. Dampen surface before applying Surface Bonding Cement.
8. Apply material a minimum of 1/8” (3.2 mm) to 1/2” (13 mm) thick.
9. For dry stack applications, material MUST BE APPLIED TO BOTH SIDES OF
THE BLOCK WALL.
Scratch/Brown/Stucco:
1. Application over masonry must follow ASTM C 926 Standard Specification
for Application of Portland Cement Based Plaster.
2. Applications over lath must follow ASTM C 1063 Standard Specification for
Installation of Lathing and Furring to receive interior and exterior portland
cement based plaster.
3. Apply material using a trowel using enough pressure to compact the
material.
4. Texture stucco to match the surrounding area using a plasterer’s trowel or
finish to desired texture.
NOTE: Check with local building code requirements for proper installation
guidelines.
Sakrete Surface Bonding Cement is
a fiber reinforced portland cement
based coating for concrete block
and masonry walls. It can be used
to build block walls without mortar
joints as well as to decorate and
damp proof existing block walls.
Features:
• High Strength >5000 psi
• Decorative Water Resistant Concrete & Masonry Coating
• Fiber reinforced to reduce shrinkage cracking
• Labor saving compared to conventional masonry construction
• Paintable
Use For:
• Building dry stack block walls without mortar
• Damp proof coating for basement and foundation walls
• Masonry parge or finish coating
• Interior or exterior
• Scratch and brown coat
Yield/Water/Coverage:
To determine coverage: Multiply Length (feet) x Width (feet) x Thickness (inches)
and divide by 12. Then divide by the yield in the chart above to determine the
numbers of bags needed. See Calculator on Sakrete.com for additional
assistance. Yield and water are approximate.
Technical Data:
Compressive Strength ASTM C 109
28 days = 5,000 psi (34.5 MPa)
COLOR:
Gray
Preparation/Application:
For best results all materials should be stored between 40°F (4°C) and 90°F
(32°C) 24 hours prior to installation.
Refer to:
- International Masonry Industry All-Weather Council (IMIAC)
- Recommended Practices and Guild Specifications for Cold Weather
Masonry Construction
- Recommended Practices and Guide Specifications for Hot Weather
Masonry Construction
Bag Size Yield/Coverage Water
50 lb (22.6 kg) Covers 35 - 40 ft
2
(3.25 – 3.7 m
2
) at
1/8” (3.2 mm) thick
5.0 to 6.0 qts
(4.7 - 5.7 L)