User's Manual

1
Remove the
plastic cover by
unscrewing the
4 screws at the
corners.
2
Attach the back
of the device to
the wall at a
suitable location
using the included
hardware.
Make sure that the fuses are each of 5 Amp,
slow blow and in the correct position.
5
AKL04PRF Zone Pump Wiring Center
Installation Guide
4
Wire the device to the AC power supply
and zone pumps using wiring appropriate
for 120VAC. Connect other terminals as
appropriate to other devices using proper
wiring. Be sure to thread wiring through
the knock outs and use cable clamps to
fasten the wiring to the device.
3
Disconnect the
AC power to the
AC wiring for the
device.
If you know you will need
an external antenna, please
follow the instructions to the
right for External Antenna
Installation.
6
7
Use the table below to configure the switches on the device. For
descriptions of the functions, see the Operational Summary to the right.
These switches are only read at power up. If you are using a wired
thermostat, need Priority Zone functionality and/or have a Primary pump
or external antenna, set the switches appropriately now. Any changes will
require AC power to be removed from the device, then restored.
8
Re-attach the plastic cover, securing
it with the 4 screws and switch on
the AC power to the unit.
The Power LED will come on and the
Network Status LED will flash red.
The device is now ready to connect to the network. Follow the steps for
the selected type of network to add the device to the network.
Local Only Network using ZigBee Coordinator
1. Plug the Coordinator into a centrally
located outlet in the home if you
have not already done so.
2. Press and hold the button on the
Coordinator until the button flashes red (about
five seconds).
The Coordinator is now ready to pair and is
looking for devices.
The Network Status LED on each wiring center
will go steady red when connected to the
Coordinator. One Coordinator can support up to
nine wiring centers.
3. Determine the network ID number for a wiring
center by pressing the Pair button briefly and
adding the numbers associated with the lit
Zone LEDs (see Version / ID# chart under LED
Indicators).
4. Pair and setup the Salus thermostats according
to the thermostat manual, using the wiring
center ID number determined in the previous
step.
5. When all thermostats are setup, press and hold
the button on the Coordinator until the button
is steady red (about five seconds).
Checking System Configuration and Communication
Coordinator to Wiring Centers
Press and hold the coordinator button for one second.
All devices connected to the coordinator will flash. To
stop checking, press and hold the coordinator button
again for one second.
9
Internet Connected Network using Basic Gateway
1. Setup the Basic Gateway as
instructed and associate the
gateway with the wyse.ly
service account.
2. Go to the Add New Equipment page
on the wyse.ly App and press “Scan for
equipment”.
The gateway ring will flash red indicating
that it is looking for devices.
3. Use the wyse.ly app to add the wiring
centers to your wyse.ly network.
The Network Status LED on each wiring
center will go steady red when connected to
the Basic Gateway.
4. Use the wyse.ly app to add the Salus
thermostats to your network and associate
them with the desired wiring center and
zone.
5. When all devices are setup, exit the Add
New Equipment function on the wyse.
ly App.
The gateway ring will turn steady blue to
indicate normal operating mode.
Checking System Configuration and Communication
Gateway to Wiring Centers
Go to the Wyse.ly App and press the Identify button
for the desired wiring center. The desired wiring
center will start flashing the G1 and G2 LEDs. To
stop the identify process, press the Identify button
on the App again.
Operational Summary
Following is a brief summary of the functions available in the AKL04PRF wiring center
to simply and safely connect thermostats and corresponding pumps.
Group Function (available only in Local Only Network)
The wiring center can have four different configurations:
One standalone thermostat for each zone (4 thermostats in total)
Two groups: Group 1 (G1), zones 1-2, with a master thermostat and optional
slave thermostat, and Group 2 (G2), zones 3-4, with a master thermostat and
one slave thermostat
Group 1 with master/slave thermostats and the other zones (3-4) with standalone
thermostats
Zones 1 and 2 with standalone thermostats and Group 2 with master/slave
thermostats
For wireless thermostats, groups are set on the thermostat during the pairing process.
When "gr flashes
on the thermostat display, pr
ess UP/DOWN arrows to select the
g
roup
number. Group “_ _” is standalone operation.
Zone Pumps
The Zone Pumps are activated when the associated thermostats call for heat, except
when a Priority Zone call is Active, in which case the pumps are turned off.
Exercise Function
When turned on, the Exercise function will turn ON a pump for 30 seconds after 72
hours of no activity on that pump.
Master/Slave Connections
The three terminals (C1, C2, and GND) can be used to connect up to
4
other wiring centers (5 total). They are wired in parallel (C1 to C1 to
C
1
, C2 to C2 to C2, etc.) with up to 100 meters from end to end. Only
one
wiring center can be the Master, the other wiring centers must be
Slaves, as determined by the position of the MASTER / SLAVE DIP switch.
ZC/N Connector (Master wiring center only)
A M
a
s
ter wiring center without Priority uses the ZC/N terminals to
enable or disable the wiring center, typically from the boiler ZR/ZC
120
VAC contacts. When 120 VAC is applied across the ZC/N terminals,
the wiring center is enabled. When 120 VAC is not applied, the wiring
center is disabled and all pumps are switched OFF.
Dry Contacts (Master wiring center only)
There are three sets of dry contacts in the wiring center.
A
UX
: Contact c
l
o
s
ur
e wh
en any pump is ON
a
nd Priority
Zone is
not
active.
XX
: Contact
closure
when
any pump is ON, including an active Priority Zone.
Zone1 E/S: Contact closure when Priority Zone is active. Can be used for self regulated pumps or other controls.
Priority Zone Function (Master wiring center only)
The Priority Zone function is usually used to give domestic hot water (DHW) priority for
the boiler output. Activating this function will change the behavior of Zone 1 on the
MASTER wiring center. When Priority is ON and the Zone 1 thermostat calls for heat,
the following occurs as part of an active Priority Zone:
Zone 1 pump is turned ON and all other pumps, including those on SLAVE wiring
centers, are turned OFF.
The Zone 1 pump runs for 1 hour, after which all zones resume their normal
operation.
The Priority
Zone function can be canceled early by having the Zone 1 thermostat
end the call for heat.
Another Priority Zone call after the 1 hour period cannot be initiated until the
Zone 1 thermostat ends the initial call for heat.
Purge Function (Master wiring center only)
Wh
e
n
turned on, the Purge function will keep the Zone 1 pump ON fo
r
2
minutes
following
th
e
end
of a
Priority Zone call. All other zones will remain off during
the purge.
Primary Pump Function (Master wiring center only)
The Primary Pump controls the heating system and it switches ON when any zone is ON,
including zones on SLAVE wiring centers, except:
PRIORITY switch is ON,
PRIMARY STATUS DURING PRIORITY switch is OFF,
and Priority Zone is Active,
WHEN: THEN: Primary Pump is OFF
External Antenna Installation
If you need to install an external antenna,
perform the following:
Disconnect power
Remove the protective cover from
the External Antenna connector on
the top edge of the board.
Pass the antenna c
able
through the antenna knock
out (and cable clamp) on the
top of the housing and screw
the cable onto the connector.
Secure the cable using a cable
clamp.
Change the Antenna Selection
switch from INT to EXT.
Reconnect power
Factory Default Reset
To restore the device to Factory Default settings, press and
hold the Pair button until both G1 and G2 LEDs go off after
becoming steady red.
Note: Restoring to Factory Default will remove the wiring
center from the network and delete all associated devices.
Definition
DIP Switch
Master
ON
OFF
Slave
MASTER/SLAVE
PRIORITY
EXERCISE
PRIMARY STATUS
DURING PRIORITY
PURGE
WIRED/WIRELESS
Zone1 is Priority Zone
Exercise ON for all pumps
Primary Pump ON during
Priority
Zone1 OFF 2 min after end
of Priority
Wired thermostat for Zone1
Zone1 is Pump Zone
Exercise OFF for all pumps
Primary Pump OFF during
Priority
Zone1 OFF at the end of
Priority
Wireless thermostat for
Zone1
IGNORED:
Zone1 is pump zone
Same as Master
IGNORED: Primary
Pump always OFF
IGNORED:
No Priority
Same as Master
The device will now use the external antenna for wireless
communication.
Note: For regulatory compliance, only the Salus A8RFA
antenna (sold separately) can be used with this device.