Salus PL07 Manual Ver007.qxd:Layout 1 10/9/10 PRODUCT COMPLIANCE This product complies with the essential requirements of the following EC Directives: • Electro-Magnetic Compatibility Directive 2004/108/EC • Low Voltage Directive 2006/95/EEC • EC Marking Directive 93/68/EEC SAFETY INFORMATION These instructions are applicable to the Salus Controls model stated on the front cover of this manual only, and must not be used with any other make or model.
Salus PL07 Manual Ver007.qxd:Layout 1 10/9/10 INTRODUCTION The PL07 from Salus Controls is a modular pump and boiler logic control module, designed specifically for heating applications.
Salus PL07 Manual Ver007.qxd:Layout 1 10/9/10 INSTALLATION Please read the important safety information at the start of this manual before you begin to install the device. NOTE: All electrical installation work should be carried out by a suitably qualified Electrician or other competent person. If you are not sure how to install this logic module consult either with a qualified electrician, heating engineer or your boiler / heating system supplier for advice on how to continue.
Salus PL07 Manual Ver007.
Salus PL07 Manual Ver007.qxd:Layout 1 10/9/10 CABLE CONNECTIONS The PL07 does not use conventional screw terminals for wiring connections, but uses cage clamp terminals. The cage clamp terminals are spring loaded and provide a very quick and secure method of making all the electrical connections to the module. Please take the following steps to make the wiring connections to the PL07: 1.
Salus PL07 Manual Ver007.qxd:Layout 1 10/9/10 4. Insert the conductors into their appropriate terminals: Cable sizes used should be within the following ranges – • Solid: • Stranded: 0.5 – 1.5mm2 1.0 – 1.5mm2 If using stranded cable, a small screwdriver can be used to open the cage clamp to allow conductor insertion. 5. Fit the protective cover: Secure the cover by turning the locking screws a quarter turn.
Salus PL07 Manual Ver007.qxd:Layout 1 10/9/10 USER INTERFACE AND CONTROLS The status and operation of the PL07 is clearly shown by the use of two green Light Emitting Diodes (LEDs) on the module front panel: When initially powering up the PL07, both LEDs will turn on for about one second before turning off. The LED indicators allow the user to see at a glance the current status of the logic module.
Salus PL07 Manual Ver007.qxd:Layout 1 10/9/10 JUMPER SETTING SUMMARY Jumper Function Default Setting J1 – Boiler and Pump protection ON – OFF Jumper in ON position OFF – Disables boiler and pump protection (immediately turns pump and boiler relays on when a thermostat calls for heat). ON – Enables boiler and pump protection (delays turning on pump and boiler relays for 3 minutes when a thermostat calls for heat).
Salus PL07 Manual Ver007.qxd:Layout 1 10/9/10 OPERATION Boiler Control The PL07 will turn the boiler on when it receives a call for heat from any of the installed thermostats via the KL06 wiring centre. Depending on the jumper settings the boiler will be turned on immediately, or after a delay of three minutes. Once the thermostats are no longer calling for heat, the boiler will be turned off immediately.
Salus PL07 Manual Ver007.qxd:Layout 1 10/9/10 The boiler and pump will be turned on by the PL07 (immediately, or after a delay of three minutes) if there is a call for heat from any of the installed thermostats. Once all the thermostats are no longer calling for heat, the boiler will be turned off immediately and the pump will be operated in accordance with the relevant jumper settings (i.e. the pump will be turned off immediately, or after a delay of three minutes).
Salus PL07 Manual Ver007.qxd:Layout 1 10/9/10 MAINTENANCE The PL07 logic module requires no special maintenance. Periodically, the outer casing can be wiped clean using a dry cloth (please DO NOT use solvents, polishes, detergents or abrasive cleaners, as these can damage the module). There are no user serviceable parts within the unit; any servicing or repairs should only be carried out by Salus Controls or their appointed agents.
Salus PL07 Manual Ver007.qxd:Layout 1 10/9/10 PRODUCT SPECIFICATION Model: Type: PL07 Controlled logic module for pump and boiler control in heating applications. Switching 1. Circulating Pump Relay: Switching Voltage: Switching Current: Contact Type: 230V AC, 50Hz 5A resistive, 2A inductive Normally Open 2.