Salus RT505TX Manual 011_89 04/09/2012 08:59 Page 1 RT RT RT5 T 50 05TX 5TX RT5 T 05TX T505TX RT50 RT R T50 505TX 5T TX RT505TX RT T505TX 5 5TX Programmable RRoom oom Thermostat RXBC605 RXRT505 RXWBC605 RXVBC605 RXST625 The RT505TX can be used with any of these receivers 868MHz
Salus RT505TX Manual 011_89 04/09/2012 08:59 Page 2 RT505TX RT505TX 2 RT505TX INSTRUCTION MANUAL
Salus RT505TX Manual 011_89 04/09/2012 08:59 Page 3 PRODUCT COMPLIANCE This product complies with the essential requirements of the following EC Directives: • • • Electro-Magnetic Compatibility directive 2004/108/EC Low Voltage Directive 2006/95/EEC EC Marking directive 93/68/EEC SAFETY INFORMATION These instructions are applicable to the Salus Controls model stated on the front cover of this manual only, and must not be used with any other make or model.
Salus RT505TX Manual 011_89 04/09/2012 08:59 Page 4 INTRODUCTION A programmable thermostat is a transmitter that combines the functions of both a room thermostat and heating controller into a single unit. The programmable thermostat is used to switch the heating system in your home on and off as needed. It works by controlling the temperature according to a series of programmed settings that take effect at different times of the day.
Salus RT505TX Manual 011_89 04/09/2012 08:59 Page 5 The ideal position to locate the RT505TX thermostat is about 1.5m above floor level. It should be mounted in a location where the thermostat is accessible, reasonably lit and free from extremes of temperature and draughts. Do not mount the thermostat on an outside wall, above a radiator or in a location where it may be subjected to direct sunlight.
Salus RT505TX Manual 011_89 04/09/2012 08:59 Page 6 If the Reset Button is pressed, the RT505TX will behave in the same way as described above, except that any previously saved user settings stored in the internal memory will be deleted and overwritten with the default settings, and all programmable thermostat control settings will be returned to default values. USER INTERFACE AND CONTROLS The status and operation of the RT505TX is clearly shown on the large backlit Liquid Crystal Display (LCD).
Salus RT505TX Manual 011_89 04/09/2012 08:59 Page 7 OPERATION The RT505TX is configured and adjusted by the use of a minimal number of user controls, and an intuitive user interface. The backlit Liquid Crystal Display (LCD) gives a highly visible, easily readable indication of the programmable thermostat status. SETTING THE TIME Press and hold SET and SELECT when the RT505TX is in Normal mode for a few seconds to enter the Clock setting mode.
Salus RT505TX Manual 011_89 04/09/2012 08:59 Page 8 PROGRAMMING THE RT505TX The RT505TX offers great versatility with its programming options, allowing the user to programme the unit to operate on a 5/2 or 7 day control cycle. The programmable thermostat has a default set of Programmes that have been designed to meet the needs of most users. If these default programmes are not suitable for your particular situation, reprogramming the RT505TX with your own settings is a very straightforward operation.
Salus RT505TX Manual 011_89 04/09/2012 08:59 Page 9 Press the UP or DOWN key to adjust the hour setting to the desired value, and confirm your selection by pressing the SELECT key. Pressing the SELECT key allows you to step through each of the items to be reviewed or adjusted within the programmes in the following sequence: Programme Function Sequence 1 6am 00 21ºC 2 8am 00 14ºC 3 4pm 00 21ºC 4 6pm 00 21ºC 5 10pm 00 14ºC …before then allowing you to cycle back to Programme 1.
Salus RT505TX Manual 011_89 04/09/2012 08:59 Page 10 Press the UP or DOWN key to adjust the hour setting to the desired value, and confirm your selection by pressing the SELECT key. Pressing the SELECT key allows you to step through each of the items to be reviewed or adjusted within the programmes in the following sequence: Programme Function Sequence 1 6am 00 21ºC 2 8am 00 14ºC 3 4pm 00 21ºC 4 6pm 00 21ºC 5 10pm 00 14ºC …before then allowing you to cycle back to Programme 1.
Salus RT505TX Manual 011_89 04/09/2012 08:59 Page 11 REVIEWING SET POINT TEMPERATURE You can view the set point temperature at any time by pressing either the UP or DOWN key.
Salus RT505TX Manual 011_89 04/09/2012 08:59 Page 12 Once in Temporary Override mode, the clock and day are displayed, along with the SET indicator; all other indicators are cleared from the display. The set point temperature will flash to indicate that it can be changed: Pressing the UP or DOWN key will increase or decrease the set point temperature in 0.5 °C steps - the set point temperature can be adjusted within a set range or 10 °C to 35 °C.
Salus RT505TX Manual 011_89 04/09/2012 08:59 Page 13 SETTING UP RF COMMUNICATION WITH YOUR RECEIVER RXRT505(ONLY) After you have switched the above receiver on, the thermostat will automatically pair. When the red LED stops flashing, the unit has successfully paired. Receiver If you have difficulty in pairing the thermostat, we recommend changing the address codes in the thermostat and the receiver.
Salus RT505TX Manual 011_89 04/09/2012 08:59 Page 14 LOCATION OF SYNC BUTTONS ON RECEIVERS RXBC605 Sync Button For full instructions on pairing the receiver refer to the RXBC605 manual. Sync Button RXST625 Press reset button first For full instructions on pairing the receiver refer to page 9 of the RXST625 manual. RXVBC605 Sync Button For full instructions on pairing the receiver refer to page 16 of the RXVBC605 manual.
Salus RT505TX Manual 011_89 04/09/2012 08:59 Page 15 TESTING THE RF TRANSMISSION 1. Press the UP button on the thermostat until the set point temperature is higher than room temperature by a few degrees. 2. Wait for a few seconds. The boiler on (heat call) indicator should appear on the bottom left of the LCD on the thermostat. 3. Check the LED on the receiver unit - it should be illuminated. 4. Press the DOWN button to adjust the set point temperature to be lower than room temperature. 5.
Salus RT505TX Manual 011_89 04/09/2012 08:59 Page 16 Sleep Mode By pressing both the UP and DOWN keys together, the RT505TX will enter SLEEP mode. In this mode, all the RT505TX functions will be paused to save battery power, with the exception of the clock which will continue to run in the background. While in SLEEP mode: • The LCD display will be blank. • All output from the thermostat will be turned off immediately. Press any key to wake up the RT505TX and cancel SLEEP mode.
Salus RT505TX Manual 011_89 04/09/2012 08:59 Page 17 PRODUCT SPECIFICATION Model: Type: RT505TX Electronic programmable thermostat, designed for RF heating applications. 868 MHz Frequency Programming Programming Modes: Number of Programmes: Override Facility: User selectable for 5/2 or 7 day option Five (5) user programmes plus factory default programme. User selectable programme override facility.
Salus RT505TX Manual 011_89 04/09/2012 08:59 Page 18 Clock Accuracy: Display: ± 1 minute per month 12 hour Frost Protection Setting: 5 ºC Environment Operating Temperature: Storage Temperature: 18 0 ºC to + 40 ºC - 20 ºC to + 60 ºC RT505TX INSTRUCTION MANUAL
Salus RT505TX Manual 011_89 04/09/2012 08:59 Page 19 RT505TX Warranty Salus Controls warrants that this product will be free from any defect in materials or workmanship, and shall perform in accordance with its specification, for a period of two years from the date of purchase. Salus Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product. Customer Name: ..........................................................................................
Salus RT505TX Manual 011_89 04/09/2012 08:59 Page 20 salus-tech. Sales: Email: sales@salus-tech.com Tel: 01226 323961 Technical: Email: tech@salus-tech.