RT RT5 T 50 05RF 5RF RT5 T 05RF T505RF Thermostat Receiver Units RT50 T505RF T 505 5RF RF RT50 RT R T50 505RF 5R RF RXST625 RXRT505 RXVBC605 This instruction manual covers the receivers above RXWBC605 886MHz
ST625TX RT505TX 0915FLTX 0915FLT RT305TX ST325TX SUPPLIED SEPERATELY
RXRT505 RXST625 RXVBC605 RXWBC605
PRODUCT COMPLIANCE This product complies with the essential requirements of the following EC Directives: • Electro-Magnetic Compatibility directive 2004/108/EC • Low Voltage Directive 2006/95/EEC • EC Marking directive 93/68/EEC SAFETY INFORMATION These instructions are applicable to the Salus Controls model stated on the front cover of this manual only, and must not be used with any other make or model.
RT RECEIVER INTRODUCTION The RXRT505 is used for the wiring connections and on/off control. The RXRT505 is linked to your thermostat via radio frequency (RF) signal. Features • LED status indication • ON / OFF switch • 868 MHz communication CONNECTING THE RXRT505 RECEIVER The RT Receiver should be mounted in a suitable location that is both accessible for the connection of mains and control wiring, and allows good reception of the RF signal.
On the front cover of the receiver you will see that there is the On/Off switch and two Light Emitting diodes (LEDs). The switch allows you to turn off the receiver if necessary to prevent it calling for heat. The top LED (red) will illuminate when the switch is in the ‘On’ position and the unit is receiving power. The top LED (green) illuminates when the receiver is receiving a heat call transmission from the thermostat.
SETTING UP RF COMMUNICATION WITH YOUR THERMOSTAT RT505TX / RT305TX After you have switched the receiver on, the thermostat will automatically pair* with the RT505TX and the RT305TX (only). When the red LED stops flashing, the unit has successfully paired. Thermostat DIP Switches Jumper Caps If you have difficulty in pairing the thermostat, we recommend changing the address codes in the thermostat and the receiver.
S-SERIES RECEIVERS INTRODUCTION The RXST625 is used for the wiring connections and on/off control. The RXST625 is linked to your thermostat via radio frequency (RF) signal. Features • LED status indication • Manual override • 868 MHz communication CONNECTING THE RXST625 RECEIVER The RT receiver should be mounted in a suitable location that is both accessible for the connection of mains and control wiring, and allows good reception of the RF signal.
TYPICAL WIRING INSTALLATIONS The RXST625 receiver is wired the same way no matter if you are wirings 240V or 24V, the receiver will always need a 240V Live and Neutral feed connected into L & N terminals. The COM and NO is to be connected to the boilers External Loop (see diagram below), if connected in this way the receiver relay can only switch voltage supplied by the boiler.
RECEIVER LED INDICATORS The LED indicators on the RXST625 receiver are designed to give a clear and easily understood indication of the current state of the system. The various LED signal combinations and descriptions of what they indicate are shown in the table below: LED State Indication Blue On Receiver is in manual mode and system is calling for heat. Blue Flashing once per second Receiver is in automatic mode and system is calling for heat.
The status of the RXST625 receiver is indicated by the use of two bicolour Light Emitting Diodes (LEDs).
MANUAL MODE Moving the slide switch to the ‘MANUAL’ position selects the manual operation mode of the RF receiver. In manual mode, the receiver ignores the RF signal from the thermostat and controls the output relay manually, based on the setting of the failsafe mode switch. FAILSAFE MODES Failsafe mode has three user selectable settings – ‘ON’, ‘CYCLE’ and ‘OFF’.
RXVBC605 RECEIVER INTRODUCTION The RXVBC605 is an integral plug-in RF boiler control. The RF boiler control is a direct replacement for the basic time clock or blanking plate usually supplied with the boiler. Installing the RF boiler control takes minutes. Once installed, you will benefit from all the control features of the Salus room thermostat. INTEGRAL RF BOILER CONTROL The Integral RF boiler control is the RF receiving unit for your RF room thermostat.
Mounting the RF Integral Boiler Control to the boiler DANGER! • 24V & 230V: Do not Touch Electrical Components or circuits • Isolate mains electricity supply before starting any work and observe all relevant safety precautions. • Follow electro static discharge precaution. Do not touch any visible PCB parts or components. 1.Switch off the boiler at its main supply. 2.Remove cover panel or existing control. 3.Insert the integral boiler control ensuring correct location of the rear Connection pins.
4. Before switching the boiler on at its mains supply, ensure the module switch is in the OFF position. 5. To ensure the boiler control is connected properly, please now move the switch to ON . The boiler should now go on and the LED on the your boiler control should illuminate. 6. Now move the switch back to AUTO .
SETTING UP RF COMMUNICATION WITH YOUR THERMOSTAT 1. Ensure the switch on the RF integral boiler module is in the AUTO 2. Gently press and hold the SYNC button with a blunt object. After 3 seconds the Boiler Control LED will flash once every second to indicate it is ready to pair and ready to receive a signal from the thermostat*. 3. The LED will turn off when pairing is successfull.
USER CONTROLS Integral RF Boiler Control A – LED This LED will be on when the thermostat is demanding heat. B – Mode Switch ON – Boiler will be on continuous AUTO – will follow instructions from the thermostat OFF – Boiler is off C – SYNC Button - This is used only for pairing the RF communications.
RXWBC605 RECEIVER INTRODUCTION The RXWBC605 comprises of an integral plug-in RF boiler control. The RF boiler control is a direct replacement for the basic time clock or blanking plate usually supplied with the boiler. Installing the RF boiler control takes minutes. Once installed, you will benefit from all the control features of the Salus thermostat. INTEGRAL RF BOILER CONTROL The Integral RF boiler control is the RF receiving unit for your thermostat.
RF Transmission The receiving range between your thermostat and the RF Boiler Control is around 100 metres in open air, however many factors can affect the RF transmission and shorten the operating distance, e.g. shielding by thick walls, foil back plasterboard, metal objects such as filing cabinets, general RF interference, and so on. The operating range is generally around 30 metres, which is large enough for most household applications.
4. First plug in the connector block C ensuring correct orientation. Remember to ensure the block is fully connected. C 5. Now locate the boiler control’s four hooks then press in and down. Replace Cover panel A. A 6.
7. Before switching the boiler on at its mains supply, ensure the module switch is in the OFF position . 8. To ensure the boiler control is connected properly, please now move the switch to ON . The boiler should now Fire and the LED on the your boiler control should illuminate 9. Now move the switch back to AUTO .
RF Boiler Control When the switch on the Boiler Module is in the AUTO position, the boiler control will automatically receive the RF signal from the thermostat and control the module output so that it switches the boiler accordingly. The user can also move the switch to the MANUAL ON position; when in this mode, the boiler will be always turned on and the LED indicator will also be lit constantly.
USER CONTROLS Integral RF Boiler Control A – LED This LED will be on when the thermostat is demanding heat. B – Mode Switch ON – Boiler will be on continuous AUTO – will follow time and temperature program in the transmitter OFF – Boiler is off C – SYNC Button - This is used only for pairing the RF communications. SETTING UP RF COMMUNICATION WITH YOUR THERMOSTAT If you find that your thermostat will not communicate with integral boiler control please follow the steps below: 1.
TECHNICAL SPECIFICATION RXRT505 Radio Frequency (RF) Settings Operating Frequency: 868 MHz Max. Operating Range: 100 metres (open air) or 30 metres (indoors) Environment Operating Temperature: Storage Temperature: 0 ºC to + 50 ºC -20 ºC to + 60 ºC TECHNICAL SPECIFICATION RXST625 Model: Type: RXST625 RF receiver, designed for ‘Volt Free’ applications.
TECHNICAL SPECIFICATION RXVBC605 Radio Frequency (RF) Settings Operating Frequency: 868 MHz Max. Operating Range: 100 metres (open air) or 30 metres (indoors) Environment Operating Temperature: 0 ºC to + 50 ºC Storage Temperature: - 20 ºC to + 60 ºC TECHNICAL SPECIFICATION RXWBC605 Radio Frequency (RF) Settings Operating Frequency: 868 MHz Max.
NOTES 26 RECEIVER INSTRUCTION MANUAL
Warranty Salus Controls warrants that this product will be free from any defect in materials or workmanship, and shall perform in accordance with its specification, for a period of two years from the date of purchase. Salus Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product. Customer Name: ........................................................................................... Customer Address: ..........................................