User's Manual

Table Of Contents
NACOS Platinum
ED 3100 G 110 / 02 (2011-10)
Operating Instructions
A-7 Target Handling
A RADAR.fm / 10.11.11
A-68
7.10 Target List
Fig. A / 13 The Target List
Additionally to the next critical (i.e. most dangerous target), a list of all targets available in the system
1)
can be displayed. The columns of the displayed table are self-explanatory, they can be sorted ascending
or descending by clicking on the appropriate title of the column. Sorting takes place in the instant of the
click, afterwards the sequence of the entries remains static, even if the values of the sort criterion
change.
If the pointer is moved on the depiction Capacity, an infor-
mation is displayed showing the percentage of memory usage
for targets. If 95% of the maximum capacity is reached, an
indication is given. If the maximum capacity is exceeded, an
alarm is given.
Maximum number of targets:
Table A / 13 Maximum Number of Targets
1)
The list includes all tracked ARPA targets and all AIS targets selected for continuous display. See chapter 3.5.2
on page III-60. The most important target data can also be assessed directly in the PPI by holding the cursor on
the target symbol. See chapter 7.2 on page A-59 for details.
Type of Target Maximum Number
ARPA 40
AIS Activated 40
AIS Sleeping > 200