User's Manual
Table Of Contents
- GENERAL
- 1 About these Operating Instructions
- 2 Safety Precautions
- 3 NACOS Platinum System Description
- 4 Multi Function Display
- 5 NACOS Platinum Graphical User Interface
- QUICK START GUIDE
- MAIN APPLICATIONS
- RADAR
- 1 General Information
- 1.1 RADAR Safety
- 1.2 Current IHO Standards / Regulatory Approvals
- 1.3 System Structure and Installation
- 1.4 Basics / Evaluation of the RADAR Video
- 1.4.1 Basics of the Evaluation of RADAR Video in Platinum Series
- 1.4.2 Achievable RADAR Range
- 1.4.3 Distortions of the RADAR Video
- 1.4.4 Undesirable Echo Displays and Effects
- 1.4.5 RADAR Setting for the Display of Racon Codes
- 1.4.6 RADAR Settings for Target Enhancer Detection
- 1.4.7 RADAR Setting for SART Detection (X-Band only)
- 1.4.8 Transmission formats
- 1.5 Basic setting of the RADAR Video
- 1.6 RADAR Accuracy
- 2 The RADAR Keyboard
- 3 An Overview of the Screen
- 4 RADAR Application Area
- 5 RADAR Sidebar - Permanent Area
- 6 RADAR Sidebar - Non-Permanent Area
- 7 Target Handling
- 7.1 Overview
- 7.2 Manual Target Acquisition
- 7.3 Manual Target Selection
- 7.4 Automatic Target Acquisition
- 7.5 Settings for Dangerous Targets
- 7.6 Settings for Acquisition/Guard Zones
- 7.7 Target Fusion
- 7.8 Deletion and Loss of Targets
- 7.9 Critical Target
- 7.10 Target List
- 7.11 Target Display
- 7.12 Trial Manoeuvre
- 7.13 Reference Target Tracking
- 7.14 ARPA Training
- 7.15 ARPA Malfunctions
- 7.16 AIS Malfunctions
- 8 User Symbols
- 9 CHARTRADAR (optional)
- 9.1 Overview
- 9.2 Basic Adjustments
- 9.3 Selecting the Objects to be Displayed in the Vector Chart
- 9.3.1 Overview
- 9.3.2 Categories of Display Groups
- 9.3.3 Select a Category
- 9.3.4 Select the Primary Chart Information Set (PCIS)
- 9.3.5 Indication of Category in the Status Line
- 9.3.6 Defining the Symbol Presentation
- 9.3.7 Setting the Display of Text Labels
- 9.3.8 Switch on Additional Information
- 9.3.9 Switch on Conditionally Displayed Features
- 9.4 CHARTRADAR Application Area
- 9.5 Application Area Context Menu
- 9.6 Setting the Depths Lines to be Displayed in the Vector Chart
- 9.7 Setting the Own Ship’s Draft
- 9.8 Activating the Chart Monitoring
- 9.9 Setting the Look-Ahead Sector
- 9.10 Chart Maintenance
- 9.11 Main Differences between CHARTRADAR and Full ECDISPILOT
- 1 General Information
- VOYAGE PLANNING AND MONITORING
- 1 Voyage Planning
- 1.1 Generation of Routes
- 1.1.1 General Information about Pre-planned Tracks
- 1.1.2 Generation, Handling and Administration of the Routes
- 1.1.3 Route Display Settings
- 1.1.4 Route Editing - Graphical
- 1.1.5 Route Editing - Text Mode
- 1.1.6 Details of the Waypoint Data
- 1.1.7 Checking of Routes
- 1.1.8 Completing the Generation of the Route
- 1.1.9 Import / Export Routes
- 1.1 Generation of Routes
- 2 Chart and Route Monitoring
- 1 Voyage Planning
- CONNING
- SENSORS
- OPTIONAL APPLICATIONS
- MAINTENANCE
- 1 Performance Monitor
- 2 Data Maintenance of the Electronic Charts
- 2.1 General
- 2.2 Starting Chart Maintenance
- 2.3 Chart Maintenance Application Area
- 2.4 Update of Charts from Media
- 2.5 Messages during Chart Update
- 2.6 Display Charts which are on a Media or a MFD (workstation)
- 2.7 Maintenance of Charts on your MFD (workstation)
- 2.8 Display Expander
- 2.9 Backup/Restore of Map Data
- 3 Manual ENC Update Editor
- 4 Hardware Maintenance
- 5 SW Version and Updates
- ALARMS
- LISTS AND INDEXES
- DOCUMENT HISTORY
NACOS Platinum
ED 3100 G 110 / 02 (2011-10)
Operating Instructions
A-8 User Symbols
A RADAR.fm / 10.11.11
A-84
8.1 Symbols
User symbols are individual user made chart objects which
can be inserted into the chart database in order to supple-
ment the official electronic charts.
The user made symbols of different kind are stored perma-
nently in the common databases on all MFD with radar or
ECDIS functionality. Deletion of selected symbols is the
only method to remove User Symbols from the database.
The common database of the User Symbols can be stored
on external memory devices like USB-Memory sticks. See
chapter 2.9 on page H-13 for details.
The User Symbols panel of the Display expander provides
different object categories:
- Symbols (position fix, anchorage area, buoys and beacons, lights, landmarks, platforms, radio
stations and wrecks etc)
- Areas (highlighted danger areas and feature areas)
- Lines (safety lines, feature lines and clearing lines)
- Events and Text (for free text information and cautions)
The following figure shows examples of user symbols:
Fig. A / 20 User symbols on the electronic chart
Switching on and off the display of User Symbols: In Presentation > Display > User Sym, or by a
MORE click into the PPI(Chart area under Layer > User Symbols)
Danger highlight (red)
Own safety line (orange; the
hatching points towards the
unsafe area)
Feature area (ochre, brown)
Feature line (orange)
Text note, information
Text note, caution
Symbols (examples)
Names and notes are
displayed if the display
of the Text Labels is
switched on