Operating Instructions
V-2 Alarm Management
V Alarms.fm / 10.11.11
V-33
NACOS Platinum
In addition, at service level, it can be specified which of the following reasons are to cause the output
of this signal too:
- The TP Waypoint Approaching alarm appeared 30 seconds ago and this alarm has not been
acknowledged.
- The TP Track Limit alarm has been triggered.
1)
- The TP Course Limit alarm has been triggered.
1)
At service level, the signal output can be set for the TP Track Limit and TP Course Limit alarms in
such a way that it takes place after a delay of 30 seconds.
The TRACKPILOT Alarm signal disappears as soon as the cause of the alarm is remedied or the alarm
that triggered the TRACKPILOT Alarm signal has been acknowledged.
At service level, it is possible to define that the TP Backup Navigator Alarm alarm appears at the
TRACKPILOT Master as soon as the TRACKPILOT Alarm signal is triggered. With this setting, the
TRACKPILOT Alarm signal remains active until the reason for the TP Alarm is no longer valid and the
TP Backup Navigator Alarm alarm is also acknowledged
2)
.
TRACKPILOT Rudder Alarm
The TRACKPILOT interface outputs this signal if
- the TP Rudder Feedback Differs alarm has been triggered, or
- the TP Rudder Relay Failure alarm has been triggered, or
- the TP Rudder Sync. Error alarm has been triggered.
1)
DNV requires BN alarm, issued 30 sec after TL and CL alarm without acknowledgement by the operator.
2)
The Trackpilot Alarm contact is used as the required system´s back-up navigator alarm output in installations with
a connection to external Bridge Alarm/Watch Alarm Transfer systems.