User's Manual
Table Of Contents
- GENERAL
- 1 About these Operating Instructions
- 2 Safety Precautions
- 3 NACOS Platinum System Description
- 4 Multi Function Display
- 5 NACOS Platinum Graphical User Interface
- QUICK START GUIDE
- MAIN APPLICATIONS
- RADAR
- 1 General Information
- 1.1 RADAR Safety
- 1.2 Current IHO Standards / Regulatory Approvals
- 1.3 System Structure and Installation
- 1.4 Basics / Evaluation of the RADAR Video
- 1.4.1 Basics of the Evaluation of RADAR Video in Platinum Series
- 1.4.2 Achievable RADAR Range
- 1.4.3 Distortions of the RADAR Video
- 1.4.4 Undesirable Echo Displays and Effects
- 1.4.5 RADAR Setting for the Display of Racon Codes
- 1.4.6 RADAR Settings for Target Enhancer Detection
- 1.4.7 RADAR Setting for SART Detection (X-Band only)
- 1.4.8 Transmission formats
- 1.5 Basic setting of the RADAR Video
- 1.6 RADAR Accuracy
- 2 The RADAR Keyboard
- 3 An Overview of the Screen
- 4 RADAR Application Area
- 5 RADAR Sidebar - Permanent Area
- 6 RADAR Sidebar - Non-Permanent Area
- 7 Target Handling
- 7.1 Overview
- 7.2 Manual Target Acquisition
- 7.3 Manual Target Selection
- 7.4 Automatic Target Acquisition
- 7.5 Settings for Dangerous Targets
- 7.6 Settings for Acquisition/Guard Zones
- 7.7 Target Fusion
- 7.8 Deletion and Loss of Targets
- 7.9 Critical Target
- 7.10 Target List
- 7.11 Target Display
- 7.12 Trial Manoeuvre
- 7.13 Reference Target Tracking
- 7.14 ARPA Training
- 7.15 ARPA Malfunctions
- 7.16 AIS Malfunctions
- 8 User Symbols
- 9 CHARTRADAR (optional)
- 9.1 Overview
- 9.2 Basic Adjustments
- 9.3 Selecting the Objects to be Displayed in the Vector Chart
- 9.3.1 Overview
- 9.3.2 Categories of Display Groups
- 9.3.3 Select a Category
- 9.3.4 Select the Primary Chart Information Set (PCIS)
- 9.3.5 Indication of Category in the Status Line
- 9.3.6 Defining the Symbol Presentation
- 9.3.7 Setting the Display of Text Labels
- 9.3.8 Switch on Additional Information
- 9.3.9 Switch on Conditionally Displayed Features
- 9.4 CHARTRADAR Application Area
- 9.5 Application Area Context Menu
- 9.6 Setting the Depths Lines to be Displayed in the Vector Chart
- 9.7 Setting the Own Ship’s Draft
- 9.8 Activating the Chart Monitoring
- 9.9 Setting the Look-Ahead Sector
- 9.10 Chart Maintenance
- 9.11 Main Differences between CHARTRADAR and Full ECDISPILOT
- 1 General Information
- VOYAGE PLANNING AND MONITORING
- 1 Voyage Planning
- 1.1 Generation of Routes
- 1.1.1 General Information about Pre-planned Tracks
- 1.1.2 Generation, Handling and Administration of the Routes
- 1.1.3 Route Display Settings
- 1.1.4 Route Editing - Graphical
- 1.1.5 Route Editing - Text Mode
- 1.1.6 Details of the Waypoint Data
- 1.1.7 Checking of Routes
- 1.1.8 Completing the Generation of the Route
- 1.1.9 Import / Export Routes
- 1.1 Generation of Routes
- 2 Chart and Route Monitoring
- 1 Voyage Planning
- CONNING
- SENSORS
- OPTIONAL APPLICATIONS
- MAINTENANCE
- 1 Performance Monitor
- 2 Data Maintenance of the Electronic Charts
- 2.1 General
- 2.2 Starting Chart Maintenance
- 2.3 Chart Maintenance Application Area
- 2.4 Update of Charts from Media
- 2.5 Messages during Chart Update
- 2.6 Display Charts which are on a Media or a MFD (workstation)
- 2.7 Maintenance of Charts on your MFD (workstation)
- 2.8 Display Expander
- 2.9 Backup/Restore of Map Data
- 3 Manual ENC Update Editor
- 4 Hardware Maintenance
- 5 SW Version and Updates
- ALARMS
- LISTS AND INDEXES
- DOCUMENT HISTORY
NACOS Platinum
ED 3100 G 140 / 04 (2011-11)
Operating Instructions
I-5 NACOS Platinum Graphical User Interface
I General.fm / 10.11.11
I-54
5.3.2 Non-Permanent Area
The lower half of the sidebar is the non-permanent area. It shows status information, parameters, tools
and controls. Some expanders are constantly visible, some can be hidden. See table below for details.
The expanders are grouped and stacked by means of so-called tabs. Click on a tab to view the subordi-
nated expanders. Using expanders you can expand and collapse, i.e. display and hide a variety of views,
controls or setting screens. The height of the non-permanent area is flexible and depends on the size of
the permanent area. If an opened expander exceeds the available space, a scrollbar is provided to scroll
up and down the contents of parts of the non-permanent area or to scroll left/right within parts of
expanders.
The controls displayed in the non-permanent area depend on the active application. For instance, the
RADAR application will display various settings screens. Machinery includes a navigation tool to browse
through large sets of mimic screens. The figure below shows an example of the non-permanent area of
the RADAR and ECDIS application:
Fig. I / 20 Sidebar – example of the non-permanent area of the RADAR application
The Alarm line expander and the optional TRACKPILOT expander have a permanent bar below the title
bar. This additional permanent bar will display information such as the latest alarm message, ioperating
mode, settings, etc. The general handling and type of expanders are described separately. The detailed
content and functionality of exoanders is part of the different application related chapters.
☞ If you open multiple expanders they often donot fit into the sidebar. In such cases, other expanders
will be closed or cut off at the lower end.
Tabs with which the
expanders are stacked
Expanders
Non-
permanent
area