Product manual

Introduction of SolarRiver-D Series Inverter
09
3.6 Dimension
Figure 4 Terminals of PV inverter
AC Output
AntennaLAN Relay
RS-485 Venting Element
DC Input
LANRS-485 RS-485
AC
DC1 DC2 Antenna Relay
M16x1.5
M16x1.5
3.4 Protection Function
Anti-islanding protection
When the local power grid shut down because of failure or equipment maintenance, SolarRiver-D series
inverter should be physically disconnected under safety conditions, so as to protect any personnel working
on the grid, in full compliance with the applicable prevailing national standards and regulations.
Grounding fault
SolarRiver-D series inverter is designed as floating connection with PV( positive and negative terminals
are not connected to ground ). When there is grounding fault, the inverter will be shut down and display
grounding fault.
More equipment protection
SolarRiver-D series can run safely in any working condition because of the following protections:
Continuous monitoring power grid, to ensure that the voltage and frequency is in the standard range;
When the environment temperature is beyond the range, inverter will limit power automatically and so on.
3.5 Terminals of Inverter
Figure 5 Dimension
So lar Ri ve r
Normal Fault
OKESC
380mm
520mm
175mm
120mm
111mm
180mm
244mm
320.5mm
21mm115mm
230mm