Product manual

It is normal that the inverter decreases the output power for thermal protection, but
if this occurs frequently, you need to check the air-cooling fin and the fan, or put the
inverter in a place which has better air flow. If the fan is too dirty, please clean it,
and if output power decreases because of electrical faults, please ask for professional
supports.
10
Introduction of SolarRiver-D Series Inverter & Operation Mode
Figure 6 Product label
Model:
SolarRiver 3400TL-D
XXX1223001
AS4777
RoHS
550V
Absolute maximum voltage(V
max
)
10.5/10.5A
Absolute maximum current(Isc)
360V
Nominal operating voltage
230VNominal operating voltage
16A
Maximum continuous current
50Hz
Nominal operating frequency
3000W
3200WMaximum power
Maximum continuous power
0.95 lagging ~ 0.95 leading
Power factor
Made in China
TM
www.samilpower.com
PV Grid-tied Inverter
IP65Ingress protection
-20/+60°C
Operating
temperature range
Protective class Class
Communication Type RS485
outdoor
S/N:
IP65Ingress protection
-20/+60°C
Operating
temperature range
Protective class Class
Communication Type RS485
outdoor
Model:
SolarRiver 4500TL-D
Made in China
TM
www.samilpower.com
PV Grid-tied Inverter
550V
Absolute maximum voltage(V
max
)
13.5/13.5A
Absolute maximum current(Isc)
360V
Nominal operating voltage
230VNominal operating voltage
22A
Maximum continuous current
50Hz
Nominal operating frequency
4000W
4300WMaximum power
Maximum continuous power
0.95 lagging ~ 0.95 leading
Power factor
XXX1223001
AS4777
RoHS
S/N:
IP65Ingress protection
-20/+60°C
Operating
temperature range
Protective class Class
Communication Type RS485
outdoor
Model:
SolarRiver 5000TL-D
Made in China
TM
www.samilpower.com
PV Grid-tied Inverter
550V
Absolute maximum voltage(V
max
)
15/15A
Absolute maximum current(Isc)
360V
Nominal operating voltage
230VNominal operating voltage
23A
Maximum continuous current
50Hz
Nominal operating frequency
4600W
4600WMaximum power
Maximum continuous power
0.95 lagging ~ 0.95 leading
Power factor
XXX1223001
RoHS
S/N:
IP65Ingress protection
-20/+60°C
Operating
temperature range
Protective class Class
Communication Type RS485
outdoor
Model:
SolarRiver 5200TL-D
Made in China
TM
www.samilpower.com
PV Grid-tied Inverter
550V
Absolute maximum voltage(V
max
)
15/15A
Absolute maximum current(Isc)
360V
Nominal operating voltage
230VNominal operating voltage
24A
Maximum continuous current
50Hz
Nominal operating frequency
4600W
5000WMaximum power
Maximum continuous power
0.95 lagging ~ 0.95 leading
Power factor
XXX1223001
AS4777
RoHS
S/N:
IP65Ingress protection
-20/+60°C
Operating
temperature range
Protective class Class
Communication Type RS485
outdoor
Model:
SolarRiver 4000TL-D
Made in China
TM
www.samilpower.com
PV Grid-tied Inverter
550V
Absolute maximum voltage(V
max
)
12/12A
Absolute maximum current(Isc)
360V
Nominal operating voltage
230VNominal operating voltage
16A
Maximum continuous current
50Hz
Nominal operating frequency
3680W
3680WMaximum power
Maximum continuous power
0.95 lagging ~ 0.95 leading
Power factor
XXX1223001
G83/1
RoHS
S/N:
IP65Ingress protection
-20/+60°C
Operating
temperature range
Protective class Class
Communication Type RS485
outdoor
Model:
SolarRiver 6000TL-D
Made in China
TM
www.samilpower.com
PV Grid-tied Inverter
550VAbsolute maximum voltage(V
max
)
15/15A
Absolute maximum current(Isc)
360VNominal operating voltage
230VNominal operating voltage
25AMaximum continuous current
50HzNominal operating frequency
5750W
5750WMaximum power
Maximum continuous power
0.95 lagging ~ 0.95 leading
Power factor
XXX12BD001
RoHS
S/N:
CEI 0-21
4 Operation Mode
standby Mode
The standby mode means that the inverter is ready but still not connect to the grid. In this mode, it will
continue to check whether PV array has enough power to feedback into grid. When the inverter has enough
power, it will change from standby mode to Checking mode.
Checking Mode
If inverter has passed dump load test and no error/fault occurs, it will start checking to deliver power.
On-grid Mode
In this mode, SolarRiver-D series inverter convert PV array’s DC into AC and feedback into grid.
Fault Mode
If any fault/error occurs, the inverter will stop delivering power until the fault/error is removed. Some fault/
error will auto recover, and some may need manual restart.
3.7 Product Label
The product label provides basic information for the inverter, which is attached to the right side of the
inverter. Pay special attention to the type of inverter and other specifications.