Product manual

12
Installation
Type
Project
No.
Description QTY Remark
Equipment 1
PV Grid-tied Inverter
1 unit
Accessories
2
Bracket
1 pc
3
Installation Kit
1set
4
Cable gland
1 set
1 pc
3 sets
Files
5
AC connector
1 pc 6
2 sets7
Product manual
1 pc 8
Quality certifcation
Packing list
DC connector assembly
Warranty card
1 pc
1 pc
1 pc
9
10
11
Table 1 packing list
RJ45 plug
for inverters without RS-485
for inverters with RS-485
Must observe the following standard and specifications strictly when installing, operating and maintaining
SolarRiver-D series inverter.
Get the permission from the local power department to combine inverter to the grid and operate by the
professional electrical engineer.
All the electrical installation must comply with local electrical installation standard.
Don't touch the other parts except terminals When installing.
There is high electrical voltage when working. Users should cut off inverter AC/DC power and external
control power and wait for at least 5 minutes before maintaining
Pay attention to surface heat of inverter. For example, the power Semiconductor Devices remain hot
when switched off.
5.3 Safety Instruction
Danger
DC voltage can be as much as 550 V, three-phase AC voltage reaches up to 270 V.
Ensure AC/DC side unplugged before installing and maintaining the inverter.
Pay attention to the rated voltage and current when design the system.
Please assess the following factors when designing PV system:
The largest input voltage of MPPT circuit in any case;
The largest input current of MPPT circuit in any case.
5.4 Installation Precaution
Checking environment where system is installed:
SamilPower suggests customer check the installation site. Do not fall into any of the following conditions:
● The ambient temperature is out the range of -20°C to +60°C.
● The altitude is 2,000 m above sea level.