Product manual

Operation
25
Figure 21 settings interface
Settings
2012-03-03 10
02 25
: :
Press Esc to Main Menu
Language
Date/Time
Clear date
Clear events
LCD contrast
Country
Input config
Reset Password
Network
AutoTest(Italy)
Factory set
Safety param
7.2.4 Historical Data
Move the cursor to the" History" and then press “OK”, the user will see the power amount histogram of
every hour. The user press the left or right arrow key to see daily electricenergy production histogram
in the current month, mensal electricenergy production histogram in the current in the current year.
7.2.5 Event List
Move the cursor to the" Event List" and then press “OK”, the user will see the list of events of inverter.
Record 100 event information at most. Press the right or left keys to select events.
7.2.6 Settings
Move the cursor to the" Settings" and then press “OK”, the user will enter the setting interface, as
shown in figure 21.
Some settings need to input password. There are 3 kinds of password: user password, installation
password and factory password. You can enter "Clear data", "Clear events", "Network" and "Reset
password" interface after inputting password.
7.3 CEI 0-21 Settings
Steps of the settings are as followings:
Step 1: Connect your laptop to the Ethernet port of inverter with an Ethernet cable and run Solar Power
Browser (V2.10.0.0 or higher). If the connection is successful, the serial number of the inverter will be
displayed in the left navigation bar.
A: When clicking on “Inverters”, the interface is shown as the following image. You can set the parameters
conforming to CEI 0-21 to all the inverters which are connected to Solar Power Browser. For detailed
settings please refer to step 2.
1. Initial user password: 111111.
2. Password is composed of 6 figures.
3. If forget password, please contact installation contractor.