Product manual
Communication and Monitoring
31
Figure 22 Ethernet communication
WAN
Router
8 Communication and Monitoring
8.1 Communication Interface
Standard configuration:
1. Ethernet: Transmit the inverter working state such as output voltage, current, frequency, fault
information to the PC machine or other monitoring system. Ethernet can achieve multi-inverter wired
network at the same time.
Optional configuration:
WIFI: Wireless connect to route. Transmit the inverter working state such as output voltage, current,
frequency, fault information to the PC machine or other monitoring system. WIFI can achieve multi-inverter
wireless network at the same time.
RS485: Achieve multi-inverter network to monitor the inverter working state such as output voltage,
current, frequency, fault information.
8.2 Communication Mode
When user want to know the information of the power system and monitor power system. We offer
following communications.
8.2.1 Ethernet Communication
You can connect inverter to Internet by router (the router is not special for inverters, you can get any
brand in the market). Then you can see the inverter’s data in any place of the world.
Hardware Requirements: computer which support windows(including xp,vista,win7), router, netting
twine, inverter(LAN mode).
Monitor mode: LAN and WAN.
LAN: Install SolarPower Browser in PC which can monitor inverters .In this mode, you can use a router
or nonuse.
If you use a router, you can monitor 254 inverters.
Parameter setting when using router:
Step 1: Enter home interface automatically after startup (If not the home interface, press “ESC” return
to the home interface).
Note!
Only choose one optional configuration when inverter is working.