SECTION 3 | Installation
LEGEND for Fig 3.14
NOTE:
For sizing of wiring and fuses, refer to the following:
(a)
DC side wiring: T
able 3.1
(b) AC side wiring: Table 3.2
L.
Line T
erminal
L-B. Line Bus Bar
N. Neutral Terminal
N-G.
Neutral to Gr
ound Bond
N-B. Neutral Bus Bar
G-B. Grounding Bus Bar
SBJ.
System Bounding Jumper
J1, 2, 4, 7, 9
Male Tab Terminals on internal Circuit Board
RY2. Relay for Neutral to Ground Bond Switching (Section 4.4.2)
BCTS.
Battery Charger T
emperature Sensor EVO-BCTS [Fig 2.5(a)]
1.
Battery Positive Input Connector (1, Figs 2.1 / 3.8)
2.
Battery Negative Input Connector (2, Figs 2.1 / 3.8)
3. Positive Input Connector for External Charge Controller (3, Figs 2.1 / 3.8)
4.
Negative Input Connector for Exter
nal Charge Controller (4, Figs 2.1 / 3.8)
5.
DC Side Grounding Terminal on EVO
TM
(5, Figs 2.1 / 3.8)
6.
RJ-45 Jack for T
emperature Sensor (6, Fig 2.1)
GE.
Gr
ounding Electrode. Also called "Ground Rod"
9. 20A Inlet Plug Connector IEC 60320 C20 (9, Fig 2.1)
10. NEMA5-15 Duplex GFCI Outlets (10, Fig 2.1)
14.
15A Built-in Br
eaker for AC output (14, Fig 2.1)
15. 20A Built-in Breaker for AC input (15, Fig 2.1)
27. "Quick Disconnect" to disconnect Neutral to Ground bond (27, Fig 3.9.2)
Cir
cuit breaker
Fuse
120 VAC Leg, Phase A
120 VAC Leg, Phase B (180° out of phase with Phase A Leg)
WARNING!
In case a Generator is used to feed AC input, please ensure that the Neutral conduc-
tor of the Generator is bonded to the chassis / frame of the Generator. Please refer to
Section 3.14.1 for details.
MISE EN GARDE!
En cas d'un générateur est utilisé pour envoyer de l'entrée CA, veuillez vous assurer que le conducteur neutre de la
génératrice est collé sur le châssis / cadre de la génératrice. Veuillez vous reporter à la section 3.14.1 pour plus de détails.
B
A