tive period of 2 Hours. If Equalization Transition Voltage Set Point “Ve” cannot
be maintained continuously / cumulatively for 2 Hr, transition to Float Stage will NOT
take place.
STATUS LED “BATT” is steady Green during this stage
The controller enters this stage from the previous Equalization Stage after the battery
voltage is held at the selected Equalization Transition Voltage Set Point “Ve” for con-
tinuous or cumulative period of 2 Hours.
This stage is the same as the Float Stage in the Normal Charging Cycle
LED INDICATIONS
Fig 4.2 LED Indications
2. STATUS LED “PV”
LED COLOR & PATTERN STATUS
Green - Steady “CHARGING”: Energy from PV Panel(s) is available at the PV
Panel(s) input terminals and voltage > 6V is also available
simultaneously at the battery terminals.
Green - Fast ashing “BATTERY OVER VOLTAGE”
- Over Voltage Disconnect protection has been activated due to
high voltage of ≥ 16V / 32V at the battery output terminals
- PV Panel(s) and Load have been disconnected
3. STATUS LED “BATT”