18 | SAMLEX AMERICA INC. SAMLEX AMERICA INC. | 19
tive period of 2 Hours. If Equalization Transition Voltage Set Point “Ve” cannot
be maintained continuously / cumulatively for 2 Hr, transition to Float Stage will NOT
take place.
STATUS LED “BATT” is steady Green during this stage






The controller enters this stage from the previous Equalization Stage after the battery
voltage is held at the selected Equalization Transition Voltage Set Point “Ve” for con-
tinuous or cumulative period of 2 Hours.
This stage is the same as the Float Stage in the Normal Charging Cycle
LED INDICATIONS
Fig 4.2 LED Indications
2. STATUS LED “PV”
LED COLOR & PATTERN STATUS
Green - Steady “CHARGING”: Energy from PV Panel(s) is available at the PV
Panel(s) input terminals and voltage > 6V is also available
simultaneously at the battery terminals.
Green - Fast ashing “BATTERY OVER VOLTAGE”
- Over Voltage Disconnect protection has been activated due to
high voltage of ≥ 16V / 32V at the battery output terminals
- PV Panel(s) and Load have been disconnected
3. STATUS LED “BATT”
SECTION 4 | Operation
2 3
4 5 6
7