Manual

18 | SAMLEX AMERICA INC. SAMLEX AMERICA INC. | 19
SECTION 7 | General Information on Batteries for
Powering Inverters
Fig. 7.1: Charging / Discharging Curves for 12 V Lead Acid Battery
TABLE 7.3 BATTERY CAPACITY VERSUS RATE OF DISCHARGE – C-RATE
C-Rate Discharge Current 
 100%
 
 83%
 
 
 60%
 50%
 40%
12 Volt Lead-Acid Battery Chart - 80˚F
Battery Voltage in VDC
Battery State of Charge in Percent (%)
0 10 20 30 40 50 60 70 80 90 100 110 120 130
16.5
16.0
15.5
15.0
14.5
14.0
13.5
13.0
12.5
12.0
11.5
11.0
10.5
10.0
9.5
9.0
C/5
C/40
C/20
C/10
DISCHARGE
CHARGE
C/20
C/3
C/5
C/10
C/100
Please note that X-axis shows %
State of Charge. State of Discharge