Instruction Manual
SPECIFICATIONS
INPUT VOLTAGE(nominal) 120 VAC, 60 HZ
OUTPUT VOLTAGE 13.8 VDC
OUTPUT RIPPLE & NOISE (On Full Load) 150 mV PEAK TO PEAK
OUPUT CURRENT, CONTINUOUS SEC-1212 10 A
SEC-1223 23A
CURRENT LIMIT SEC-1212 14A
SEC-1223 25A
COOLING SEC-1212 - CONVECTION COOLED
SEC-1223 - TEMPERATURE CONTROLLED FAN
PROTECTIONS OVER CURRENT, SHORT CIRCUIT AND
OVER VOLTAGE (Through PWM Controller)
OVER TEMPERATURE SHUT DOWN (SEC-1223)
ENVIRONMENTAL TEMP. RANGE SEC-1223 0 - 40
o
C
SEC-1212 0 - 30
o
C
CONNECTIONS
AC INPUT: DETACHABLE POWER CORD C/W NEMA 5-15P PLUG
DC INPUT: TERMINALS WITH TUBULAR HOLE DIA. 0.2” (5mm)
WITH SET SCREW
FUSE RATING 5 MM X 20 MM GLASS FUSE, 125V or 250 V
(Time Delay / Slow Blow)
Bussmann Littelfuse
SEC-1212 - 3A GDC-3 239003
SEC-1223 - 6.3 A GDC-6.3 21806.3
DIMENSIONS ( W X D X H ), INCHES 7.0 X 8.25 X 2.2
WEIGHT SEC-1212 3 LBS. NET
SEC-1223 3.5 LBS. NET
SAFETY CERTIFICATION UL60950-1, E179076
EMC CONFORMITY FCC Part 15(B), Class B Digital Device
NOTE: SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
11.