Product manual

Series B900-N and B900SW-N Manifold Mounted Electric Guns
14
Part 1041221B
E 2006 Nordson Corporation
Table 3 DuraBlue Operating Parameters for B900 Gun Set-up
12
Change Hose 1 Output to Electric Gun
Activation
Description:
Changes the proportioned 240 VAC
current that is provided to the hose 1
heater to a switched 240 VAC current
that is used to activate a
manifold-mounted electric gun.
Value:
0 (disabled)
1 (enabled)
Resolution:
Default Value:
0 (disabled)
Format:
Use:
Use only when a Nordson
manifold-mounted electric gun is
installed and a switching device is
connected to the melters switch
receptacle.
13
Change Hose 2 Output to Electric Gun
Activation
Description:
Changes the proportioned 240 VAC
current that is provided to the hose 1
heater to a switched 240 VAC current
that is used to activate a
manifold-mounted electric gun.
Value:
0 (disabled)
1 (enabled)
Resolution:
Default Value:
0 (disabled)
Format:
Use:
Use only when a Nordson
manifold-mounted electric gun is
installed and a switching device is
connected to the melters switch
receptacle.