Product manual
Series B900-N and B900SW-N Manifold Mounted Electric Guns
24
Part 1041221B
E 2006 Nordson Corporation
Cleaning Nozzles (contd)
Problem Possible Cause Corrective Action
5. Gun fails
to heat
Poor electrical connections Check all wires and wire
terminations in the output
connector and RTD circuit and
repair as needed. Refer to the
wiring diagram. With the system
power off, disconnect the gun
cordsets from the melter. Check
for heater and RTD continuity
through the wires to gun. Also
check the heater from wire to
ground to ensure that a wire is not
grounded. Replace if there is no
continuity or if a heater wire is
grounded.
Incorrect system settings Verify system settings. Refer to
the melter manual.
Defective heater or RTD Check the resistance of the RTD
and heater across the appropriate
pins on the gun cordset. If the
resistance is not correct, replace
the RTD or heater. Refer to the
wiring diagram and resistance
data.
6. Gun
overheats
Incorrect system voltage Ensure that system voltages
match.
Temperature settings too high Check the component
temperature settings.
Defective RTD Unplug the gun cordset and verify
that the RTD connections are
secure. If the connections are
secure, check the continuity and
resistance of the RTD across the
RTD pins on the cordset. If there
is no continuity, replace the RTD.
Refer to the wiring diagram.
Continued...