Product manual

Series B900-N and B900SW-N Manifold Mounted Electric Guns
26
Part 1041221B
E 2006 Nordson Corporation
Cleaning Nozzles (contd)
Problem Possible Cause Corrective Action
9. Gun will
not trigger
adhesive
will not
dispense
Gun not heating correctly See above.
Poor electrical connections Check all wires and wire
terminations in the hose heater,
output connector, and RTD circuit.
With system power off,
disconnect the gun cordsets from
the melter. Check the heater and
RTD continuity. Also check each
heater through wire to ensure the
wire is not grounded. Replace
the hose if there is no continuity
or if a heater wire is grounded.
Incorrect component wiring Check all wires and wire
terminations in the hose heater,
output connector, and RTD circuit
and repair as needed. Refer to
the wiring diagrams under
Technical Data as needed.
Defective coil Unplug the gun cordset and
check the coil resistance across
the coil pins on the cordset.
Refer to the wiring diagrams and
resistance data under Technical
Data as needed.
Module stroke not properly
adjusted
Adjust the module stroke. Refer
to Adjusting the Module Stroke
under Installation.
Blockage in module or nozzle Disassemble and reassemble the
module, removing blockages and
cleaning parts as needed. Refer
to Replacing a Module
Component under Repair.
Adhesive viscosity too high Increase the overall system
temperature (melter, hoses, and
guns). If there is no change,
consult the adhesive vendor.
NOTE: Do not exceed material
specifications.
System not up to operating
temperature
Allow system to heat. Refer to
the melter manual for other
related problems.
Continued...