Product manual
Series B900-N and B900SW-N Manifold Mounted Electric Guns
38
Part 1041221B
E 2006 Nordson Corporation
Replace an RTD (contd)
See Figure 14.
RTD
2
1
3
4
Figure 14: Splicing RTD leads
1. Old RTD lead
2. Heat shrink tubing
3. Parallel wire splice
4. New RTD lead
6. Strip about 6 mm (0.25 in.) of insulation from the old RTD leads.
7. Cut the heat shrink tubing from the kit in half (into two 25 mm [1 in.] pieces) and slide a
piece of heat shrink tubing onto each of the old RTD leads.
8. Cut the new RTD leads about 50−76 mm (2−3 in.) from the RTD element and strip about
6 mm (0.25 in.) of the insulation from the new RTD leads.
9. Use a parallel wire splice to crimp the exposed wire of one old and one new RTD lead
together. Repeat for the other old and new RTD leads.
10. Slide the heat shrink tubing over the splices and heat it to shrink the tubing around the
splices.
11. Install the new RTD in the manifold and apply heat sink compound (P/N 900298).