Specifications

11
Solenoid-pilot operated
Solenoid-Pilot return
(detented)
Controlled (Inlet) Pressure
EXPilot INPilot
psi bar psi bar
0-200 0-14 15-175 1-12
Auxiliary pilot
pressure required
15-175 1-12 none none
8.33
211.6
3.38
85.9
4.05
111.6
2.77
6.53
1.2
30.5
2.48
63
” NPT
Expilot port
” NPT
Expilot port
24
610
Lead
Length
A
IN EX
Solenoid-Pilot Operated/
Solenoid-Pilot Return; (detented)
EXPilot type
INPilot type
BGG-3308-316-(*) BGG-3328-316-(*)
(*) Specify Options (below) & coil code (page 9).
-3
-HT
-HC
-H2
-ME
CONTINUOUS DUTY SOLE-
NOID and/or HIGH AMBIENT
OR MEDIA TEMPERATURE:
Recommended when coil may
be energized for long periods
and/or when ambient or media
temperature will exceed 120°F
(50°C). Standard on all sole-
noids for hazardous locations.
CLASS H COIL: Recommended
for applications above 150°F
(65°C) and for DC continuous
duty above 120°F (50°C). Not
available with DIN style coil and
connector.
DIN STYLE COIL & CONNEC-
TOR: DIN type coil with 3 spade
terminals and mini-DIN connec-
tor with PG9 cord grip. NEMA 4/
IP65.
THREADED SOLENOID-PILOT
EXHAUST: Adapter attaches
to solenoid to provide 1/8 NPT
threaded port for piping of sole-
noid exhaust.
MANUAL OVERRIDE: Manually
pressurized pilot of solenoid pilot
actuator. Unguarded type push
and hold to operate. Use for set-
up or when power to solenoid is
absent.
DIMENSIONS: Inch
mm
Sufx Options: