Specifications

13
PRESSURES
Controlled (inlet) pressure & auxiliary pilot pressure (when required) are
the same as those shown for the corresponding solenoid valve for non-
hazardous locations, Pages 10 & 11.
PRESSURES
Controlled (inlet) pressure & auxiliary pilot
pressure (when required) are the same as those
shown for the corresponding solenoid valve for
nonhazardous locations, Pages 10 & 11.
A
IN EX
A
IN EX
A
IN EX
A
IN EX
A
IN EX
A
IN EX
4.22
107.1
6.08
154
COIL CAN BE ROTATED TO FRONT OR
BACKSIDE OR TURNED UPSIDE-DOWN
2.56
65
4.22
107.1
⅛” NPT PILOT PORT
(FOR EXPILOT VALVES ONLY)
CONDUIT ENTRY
SEE IDENTIFICATION DETAIL
ADAPTER (OPTIONAL)
⅛” OR ¼” NPT OR G⅛ OR G¼ (S.D. -H2 OR -H)
TOP VIEW
.55
14
2.36
60
CAN BE ROTATED
THROUGH 360°
” NPT PILOT
PORT (EX-PILOT
VALVES ONLY)
.66
16.8
3.47
88.1
.66
16.8
1.75
44.5
1.12
28.5
¼” NPT (3 PORT)
.63
15.9
1.13
28.8
.75
19.1
4.68
118.9
.63
15.9
1.5
38.1
2.5
63.5
ø
” NPT OR ¼” NPT SOLENOID ADAPTER OPTIONAL (SUFFIX -H2 OR -H)
CONDUIT ENTRY
½” NPT FOR XDBS
OR
M20X1.5 FOR XDBS
EXTERNAL
GROUND
CONNECTION
4.12
104.7
Valves For Hazardous Locations - 3/2-(Three-Way) Valves
Solenoid-Pilot Operated/Spring Return
N. O. N. C.
EXPilot type
INPilot type
EXPilot type
INPilot type
Solenoid-Pilot Operated/
Solenoid-Pilot Return; detented (not shown)
EXPilot type:
INPilot type
:
Solenoid-Pilot Operated/
Solenoid-Pilot Return; detented (not shown)
Sufx Options:
-H2 Threaded solenoid-pilot exhaust adapter, with ⅛” NPT thread
-H Threaded solenoid-pilot exhaust adapter, with ¼” NPT thread
(m) ENCAPSULATION
(e) INCREASED SAFETY
Valves with -XMA or -XMF type solenoids are ATEX certied.
(*) Specify options (at left) & coil code (page 9).
Specify solenoid S: M20 x 1.5 conduit entry
identication detail. T: ½” NPT conduit entry
Solenoid-Pilot Operated/ Spring Return
BSG-3308-316-XMA†-(*)
BSG-3308-316-XMF†-(*)
BSG-3328-316-XMA†-(*)
BSG-3328-316-XMF†-(*)
BGG-3308-316-XMA†-(*)
BGG-3308-316-XMF†-(*)
BGG-3328-316-XMA†-(*)
BGG-3328-316-XMF†-(*)
BSG-3306-316-XMA†-(*)
BSG-3306-316-XMF†-(*)
BSG-3326-316-XMA†-(*)
BSG-3326-316-XMF†-(*)
EXPilot type:
INPilot type:
†Specify solenoid identication detail.
(*) Specify coil code (page 9).
A: M20 x 1.5 conduit entry;
E: Cable gland for 6-12 mm ø cable;
F: ½” NPT conduit entry;
G: Cable gland for 9-16 mm ø cable
N. O.
N. C.
DIMENSIONS: Inch
mm
(d) FLAMEPROOF
(e) INCREASED SAFETY
Valves with -XDBS or -XDBT type solenoids are ATEX IEC CSA INMETRO certied.
BSG-3306-316-XDB†-(*) BSG-3308-316-XDB†-(*)
BSG-3326-316-XDB†-(*)
BSG-3328-316-XDB†-(*)
BGG-3308-316-XDB†-(*)
BGG-3328-316-XDB†-(*)
See page 8/9 for additional solenoid