Specifications
15
OPERATING PRESSURE
AND WEIGHT
Weight
SYSTEM PRESSURE
ALLOWABLE BACKPRESSURE
at Outlet Port (Two-Way)
or Exhaust Port (Three-Way)
Two-Way (2/2)
Block & Bleed
MS02-3-316
0.77 lbs.
(.35kg)
0-150 psi
(0-10 bar)
0
Three-Way (3/2)
Charge & Bleed
MS03-3-316
1.0 lbs.
(.45 kg)
0-150 psi
(0-10 bar)
0
.50
12.7
2.61
66.4
.92
23.3
¼” NPT
PORT
.31
7.9
MAX PANEL
1 LOCK NUT
MAX PANEL
2 LOCK NUT
3.79
96.1
Ø
1.81
46
.50
12.7
3.53
89.5
.92
23.3
¼” NPT
PORT
.31
7.9
MAX PANEL
2 LOCK NUT
4.70
119.3
.50
12.7
3.53
89.5
.92
23.3
¼” NPT
PORT
.31
7.9
MAX PANEL
1 LOCK NUT
MAX PANEL
2 LOCK NUT
4.70
119.3
EX
IN
EX
IN
OUT
Designed for use in emergency shut down systems,
Manual Shut-Off valves are available in two types.
The Two-Way (2/2) valve is designated as a Block &
Bleed valve. When the panel knob is pulled out, supply
pressure is dumped to atmosphere.
The Three-Way (3/2) valve is designated as a Charge &
Bleed valve. In the normal operating mode of this valve
the inlet port is connected to the outlet port and the ex-
haust port is blocked. When the panel knob is pulled
out, supply pressure to the outlet port is blocked and the
downstream pressure is dumped to atmosphere.
Any backpressure to the outlet port of either valve while
functioning in the normal mode, will cause the valve to
shift as if the panel knob were pulled out.
MANUAL SHUT-OFF VALVES
STAINLESS STEEL CONSTRUCTION
Materials
Porting Size and Flow
General Description
Installation
- Valve body and caps: 316 stainless steel (meets NACE
Standard MR-01-75)
- Valve Seals: FKM (Fluorocarbon) O rings
- Screws: stainless steel
- Lid Knob: synthetic resin.
Inlet, outlet & exhaust ports: ¼” NPT
Internal orice: ⅜” (9.5 mm) ø
Valves have no limitations on mounting orientation. Valves
can be panel mounted. Panel hole required: 1” (25.4 mm) ø
THREE-WAY (3/2)
CHARGE & BLEED
TWO-WAY (2/2)
BLOCK & BLEED
Product Number Button Color Product Number Button Color
Red
Black
Black
Red
MSO2-3-316
MSO2-3-316-125B
MSO3-3-316
MSO3-3-316-125B
DIMENSIONS: Inch
mm