Specifications

20
BAA-3308-900R BAA-3308-550R
Construction:
Body.
Internals, Caps
316 stainless steel
(NACE MR-01-75)
Hardcoated Aluminum
(MIL-A-8625E, Type III, Class1)
Stainless steel Fasteners- Stainless steel
FKM (uorocarbon) O rings Seals- FKM (uorocarbon) O rings
25-130 psi (1.7-8.8 bar)
Pressures:
Working (Controlled)
pressure range-
15-120 psi (1- 8.2 bar)
5 psi (0.3 bar)
Maximum allowable
exhaust backpressure-
5 psi (0.3 bar)
See Charts A & B below Pilot trip/reset- See Charts A & B below
Consult Factory Flow: Consult Factory
Air - 40 to 50 micron ltration
recommended
Media:
Air - 40 to 50 micron ltration
recommended
1/4” NPT
1/8” NPT
Porting:
Valve Ports-
Pilot Ports-
1/4” NPT
1/8” NPT
Panel Mount (1”ø hole) Mounting & Installation: Panel Mount (1”ø hole)
Red (black character “R”)
Green (black character “G”)
Indicator colors:
Trip mode (depressurized)-
Working mode (pressurized)-
Red (black character “R”)
Green (black character “G”)
(Consult factoru for other color availibility)
Pressure Chart “A” (working range): Indicating Relay-Transmitting type
Indicating
Relay Valve
Inlet Pressure
BAA-3308-900R
PSIG 25 30 40 50 60 70 80 90 100 110 120 130
BAR 1.7 2.0 2.7 3.4 4.1 4.8 5.4 6.1 6.8 7.5 8.2 8.8
BAA-3308-550R
PSIG 15 20 30 40 50 60 70 80 90 100 110 120
BAR 1.0 1.4 2.0 2.7 3.4 4.1 4.8 5.4 6.1 6.8 7.5 8.2
Minimum
Reset- Pilot
Pressure
BAA-3308-900R
PSIG 25 30 37 45 54 63 72 77 85 92 100 110
BAR 1.7 2.0 2.5 3.1 3.7 4.3 4.9 5.2 5.8 6.3 6.8 7.5
BAA-3308-550R
PSIG 15 18 24 29 35 40 46 51 57 61 65 74
BAR 1.0 1.2 1.6 2.0 2.4 2.7 3.1 3.5 3.9 4.2 4.4 5.0
Pressure Chart “B” (shut-down range): Indicating Relay-Transmitting type
Indicating
Relay Valve
Inlet Pressure
BAA-3308-900R
PSIG 25 30 40 50 60 70 80 90 100 110 120 130
BAR 1.7 2.0 2.7 3.4 4.1 4.8 5.4 6.1 6.8 7.5 8.2 8.8
BAA-3308-550R
PSIG 15 20 30 40 50 60 70 80 90 100 110 120
BAR 1.0 1.4 2.0 2.7 3.4 4.1 4.8 5.4 6.1 6.8 7.5 8.2
Minimum Trip-
Pilot Pressure
BAA-3308-900R
PSIG 10 16 22 28 35 42 50 57 63 70 77 85
BAR 0.7 1.1 1.5 1.9 2.4 2.9 3.4 3.9 4.3 4.8 5.2 5.8
BAA-3308-550R
PSIG 1 4 10 15 21 26 32 37 44 47 53 59
BAR 0.07 0.3 0.7 1.0 1.4 1.8 2.2 2.5 3.0 3.2 3.6 4.0
DIRECTION OF
AC TUATION
(INDICATOR)
GREEN RED
PILOT EXHAUST
(SIGNAL)
Indicating Relays-Transmitting type
Main Supply Relay Valve
e.g. BAA-3309-900W See page 18.
to main
system
Sensor
Sensor
Sensor
Ø
.27
6.9
(3 MOUNTING
HOLES)
Ø
1.0
25.4
MIN PANEL HOLE
WRENCH FLAT
1.37
34.8
.50
12.7
.56
14.2
1.0
25.4
.50
12.7
MAX PANEL
THICKNESS
2.38
60.5
” NPT PILOT EXHAUST PORT
¼” NPT (3 PORT)
2.0
50.8
1.38
35.1
6.21
157.7
1.08
27.4
Indicating Relay – Pilot Monitoring Valves
Series
B900 & B550 VALVES
STAINLESS STEEL
HARDCOATED ALUMINUM
CONSTRUCTION
Indicating Relay valves are used to monitor the pilot actuators
of the Main Supply Relay valves listed on pages 16-19. The
Indicating Relays have two functions. First, to indicate visually
on a panel that a circuit malfunction has occurred and sec-
ondly, to quickly cause operating pressure to exhaust from the
system through the Main Supply Relay valve, allowing a valve
operator or pneumatic system to shut-down. When placed in
series with other Indicating Relays, only the relay indicator of
the relay controlling the circuit for which a malfunction is
sensed will show red (R).
Three types of Indicating Relays are available:
First Out Indicator-Transmitting type (page 20)
First Out Indicator-Receiving type (page 21)
First Out Indicator-Bypass type (page 22)
Operation Mode A
Flow path is open between the Relay inlet and
“CYL” port whenever both the Relay inlet and
pilot pressure are within the working pres-
sure range in Chart A. In this condition the
Relay indicator is green (G). If the Relay inlet
pressure is lost while in this mode, the Relay
ow position and
indicator color will remain
unchanged.
Operation Mode B
Flow path is open between the Relay “CYL”
port and exhaust port whenever the Relay pilot
chamber backpressure does not exceed the
specications in Chart B. In this condition the
Relay indicator is red (R). The relay will auto-
matically reset to operation mode A when both
the Relay inlet and pilot pressure return to the
working range, as indicated in Chart A
FIRST OUT INDICATOR/INDICATING RELAY-TRANSMITTING TYPE
Transmitting Relay Circuit
(system in mode A - working range)
Dimensions are approximate.
Consult factory for actual
dimensions of specic valves.