Specifications
8
Sufx
Identication
Protection
Classication
Area Classication
and (Gas Grouping)
Certication-
(Conformance)
Ingress
Protection
None or
-U
General Purpose Indoor & Outdoor CSA NEMA 1,2,3
-HC
-HCC (Shown)
General Purpose Indoor & Outdoor CSA
NEMA 4,
IP65
Sufx
Identication
Protection
Classication
Area Classication
and (Gas Grouping)
Certication-
(Conformance)
Ingress
Protection
-XX
Hazardous
Locations
CLASS I, DIV. 2 (A & B)
CLASS I, DIV. 1 (C & D)
CLASS II, DIV. 1 (E, F & G)
UL - CSA NEMA 7 & 9
-LB-XX
-XN
(d) Flameproof
Ex d IIB+H2 T3 to T6 Gb
II 2 G Ex d IIB+H2 T3 to T6
IECEx
IECEx ATEX
P66
&
IP68
-LB-XN
-XDBS*
-XDBT*
(d) Flameproof
(e) Increased Safety
EX II 2 G D
Ex d e IIC T* Gb
EX tb IIIC T* ºC Db
Class I Div I Grp B, C & D
Class I Div II Grp E, F & G
EX d IIC DIP A21 T6 T4
ATEX
ATEX - IECEx
-INMETRO
CSA
IP66, IP67,
& IP68
NEMA 4, 4X
6P
-XMAA
-XMAE
-XMAF
-XMAG
(mb) Encapsulation
(e) Increased Safety
(tD) Tight Dust
Ex e mb II T5, T6 Gb
Ex tD A21 T100ºC, T85ºC Db
II 2 G Ex e mb II T5, T6
II 2D Ex tD A21 T100ºC, T85ºC
IECEx
ATEX
IP66
&
IP67
-XMFA
-XMFE
-XMFF
-XMFG
-XIFA
-XIFE
-XIFF
(ia) Intrinsic Safe
Ex (ia) IIC T4...T6 Gb
Ex (ia) IIIC T130ºC, T80ºC Db
II 2 G Ex ia IIC T4...T6
II 2 D Ex iaD 21 T130ºC, T80ºC
IECEx
ATEX
IP66
&
IP67
-XISX6
II 2 G EEx ia IIC T6
ATEX
IP65
-XISC
Intrinsic Safe
Class I, Groups (A, B, C & D)
Class II, Groups (E, F, &G)
Class III
Factory Mutual CSA
SERIES B316 VALVES
STAINLESS STEEL CONSTRUCTION
Solenoid/Pilot Operates Valves- 3/2-(Three-Way) Valves
Solenoid-Pilot actuated Series B316 valves are available with a variety of different solenoids for both nonhazardous and hazardous
locations. Basic details of actuators are listed below. For additional data consult factory.
Non Hazardous Locations Solenoids
HAZARDOUS LOCATION SOLENOIDS
*Consult factory for XDAS and XDAT operators.
See “Miscellaneous” column page 9 for ordering information.