PRODUCT NUMBER COIL CODES: Complete product numbers require, when applicable, a coil code that represents the desired coil current type, frequency and
voltage. The coil code takes the form shown below, with ratings and voltage substituted as required.
Voltage
(Power)
Electrical
Characteristics
Miscellaneous
All usual 50 Hz & 60 Hz AC (6W)
All usual DC (7W)
Class F epoxy molded coil (155ºC).
Continuous duty, 2 leads 24” (60 cm).
Steel cover with 1/2 NPT conduit entry.
24V60, 120V60, 240V60 (8.5W)
24V50, 110V50, 220V50 (8.5W)
12VDC, 24VDC, 48VDC (10.5W)
Class F epoxy molded coil (155ºC), with 3
spade terminals and mini DIN socket with
PG9 cable gland. Continuous duty.
3 spade terminals & DIN connector with PG9
cable gland: (-HC)
1/2 NPT conduit entry: (-HCC)
Voltage
(Power)
Electrical
Characteristics
Miscellaneous
All usual 50 Hz & 60 Hz AC (5.6W)
All usual DC (7.2W)
Class F epoxy molded coil (155ºC).
Continuous duty.
3 leads 24” (60 cm).
Plated steel coil housing with 1/2 NPT conduit entry.
For stainless steel (182FM) coil housing add: (-ST)
12V60, 24V60, 48V60, 120V60,
240V60 (1.8W)
6VDC, 12VDC, 24VDC, 48VDC
(1.8W)
Plated steel coil housing
with 1/2 NPT conduit entry.
For stainless steel (182FM ) coil housing add: (-ST)
Maximum pilot pressure 120 psi (8 bar).
1.8W nominal power.
All usual 50 Hz & 60 Hz AC (5.6W)
All usual DC (7.2W)
Plated steel coil housing
with M20 x 1.5 conduit entry.
Ground terminal on cover.
For stainless steel (182FM) coil housing add: (-ST)
12V60, 24V60, 48V60, 120V60,
240V60 (1.8W)
6VDC, 12VDC, 24VDC, 48VDC
(1.8W)
Plated steel coil housing
with M20 x 1.5 conduit entry.
Ground terminal on cover.
For stainless steel (182FM) coil housing add: (-ST)
Maximum pilot pressure 120 psi (8 bar)
1.8W nominal power.
24VDC (D024)
120V60 (A120) 110V50 (E110)
230V50 (E230)
1.8 Watt standard, for lower watt
contact factory.
Epoxy molded coils rated for continuous
duty, Class H – 180°C.
24VDC (4W)
(Consult factory for other voltage
options)
Continuous duty. Coil & Rectier, includ-
ing surge suppression, potted within
housing.
Thick wall epoxy coil housing with integral
junction box. Internal ground terminal.
M20 x 1.5 conduit entry: (-XMAA), (-XMFA),
Cable gland for 6-12 mm ø cable: (-XMAE), (-XMFE)
1/2 NPT conduit entry with adapter: (-XMAF), (-XMFF)
Cable gland for 9-16 mm ø cable: (-XMAG), (-XMFG)
24VDC
(10W inrush, 2.6W holding)
(Consult factory for other voltages)
Continuous duty. Coil & Power Controller
potted with in housing.
24VDC (0.8W)
(Consult factory for other voltages)
Continuous duty. Coil and power control-
ler potted within housing.
requires the use of an approved safety barrier or isolator.
Thick wall epoxy coil housing and integral
junction box. Internal ground terminal.
M20 x 1.5 conduit entry: (-XIFA)
Cable gland for 6-12 mm ø cable: (-XIFE)
1/2 NPT conduit entry with adapter: (-XIFF)
24VDC
system voltage prior to barrier
(1.6 watt max.)
Class F epoxy molded coil (155ºC).
Continuous duty.
Requires the use of an approved barrier or isolator.
Maximum operating system voltage before barrier 28VDC.
Maximum pilot pressure 115 psi (8 bar).
3 spade terminals & DIN connector with PG9
cable gland: (-HC)
1/2 NPT conduit entry: (-HCC)
Stainless steel coil housing with
internal Junction Box. Internal and
external ground screw.
Sufx Detail Ordering Code
M 20 Connection ½” Connection
No Diode Diode No Diode Diode
Standard (vent to atmosphere) XDBS1 XDBS5 XDBT1 XDBT5
1/8” Adapter (-H2E) XDBS2 XDBS6 XDBT2 XDBT6
1/4” Adapter (-H2) XDBS3 XDBS7 XDBT3 XDBT7
Dust Nut (-L14) XDBS4 XDBS8 XDBT4 XDBT8
Rating Code
A = 60Hz frequency
D = Direct Current (DC)
E = 50Hz frequency
Voltage
(Indicated by three digits:
as example,
24 volts = 024
120 volts = 120.