Datasheet

General
ENVIRONMENTAL CHARACTERISTIC
The Environmental characteristic test should satisfy the test method, procedure, and standard.
If there is no special comment, Each test performs in standard state.
(temperature 20, humidity 65%RH, pressure 1023mbar)
item
Permissible deviation
Test method
Resistor Jumper
Termination
strength
No mechanical
damage, or sign of
disconnection
Same as
left
Standard : JIS C 5201-1 4.16
Test time : applying pressure for 10 seconds
Test tension : 0603,1005,1608 - 3N (300g
f)
Others (500g
f)
Withstanding
soldering heat
1. No mechanical
damage
2.
Δ
R should be
within
±
(1%+0. 05
)
50m
Maximum
Standard : JIS C 5201-1 4.18
Temperature : 260
±
5
Test time : 10
±
1second (both side dipping)
Test procedure : measures after 24 hours
Vibration
1. No mechanical
damage
2.
Δ
R should be
within
±
(1%+0. 05
)
50m
Maximum
Standard : JIS C 5201-1 4.22
Test amplitude : 1.5mm
Test procedure : frequency 10Hz - 55Hz -
10Hz each 2 hours in x, y, z direction.
item
Permissible deviation
Test method
Resistor Jumper
Temperature
cycle
1. No mechanical
damage
2.
Δ
R should be
within
±
(1%+0.1
)
50m
Maximum
Standard : JIS C 5201-1 4.19
Test procedure : <Table 11>
Measure : after 100 cycles of procedure
Test board : <Fig 11>
Moisture
resistance life
1. No mechanical
damage
2.
Δ
R should be
within <Table 12>
50m
Maximum
Standard : JIS C 5201-1 4.14
Test condition : temp 40
±
3
, humid 90 ~
95% R H
Test voltage : rated voltage
Test time : repeat 90min ON, 30min OFF
during 1000
+4 8
hours
Test board : <Fig 11>
item 1 2 3 4
temp(
) -55
±
2 5~35 125
±
2 5~35
time(min) 30 15 30 15
<Table 11>
<Table 12>
Range(
)
Δ
RMAX
1≤R<10 ±
5%
10 R < 1M ±(3%+0.1Ω)
1M R < 10M ±
5%