Datasheet

General
RELIABILITY TEST CONDITION
Jumper's reliability test data are only applied to General type resistor.
ELECTRICAL CHARACTERISTIC
The electrical characteristic test should satisfy the test method, procedure, and standard.
If there is no special comment, Each test performs in standard state.
(temperature 20, humidity 65%RH, pressure 1023mbar)
item
Permissible deviation
Test method
Resistor Jumper
DC resistance
DC resistance value
should be within the
specified resistance
tolerance.
50m
Maximum
Standard : JIS C 5201-1 4.5
Test voltage : <Table 8>
Applying time : within 5 seconds.
Test board : <Fig 11>
Temperature
Coefficient
of
Resistance
-
Standard : JIS C 5201-1 4.8
Temp. : 20
℃→
-55
℃→
20
℃→
125
℃→
20
Test board : <Fig 13>
Calculation :
TCR(ppm/
)=
T
0
:20
±
2
R
0
:ResistanceatT
0
(
)
T : Test temperature ( -55, 125
)
R : Resistance at T (
)
Short time
overload
(STOL)
1. No mechanical
damage
2.
Δ
R should be
within
±
(1%+0.1
)
50m
Maximum
Standard : JIS C 5201-1 4.13
Test voltage : 2.5 times of rated voltage Max.
surge current at the Jumper.
Applying time : 5 seconds
Test board : <Fig 12>
Intermittent
overload
(IOL)
1. No mechanical
damage
2.
Δ
R should be
within
±
(3%+0.1
)
50m
Maximum
Standard : JIS C 5201-1 4.13
Test voltage : 2.5 times of rated voltage Max.
surge current at the Jumper.
Test method : 1 sec ON, 25 sec OFF
10,000
+400
cycles
Test board : <Fig 12>
<Table 8>
Range (
)
Voltage (V)
1≤ R < 10
0.1
10 R < 100
0.3
100 R < 1K
1.0
1K R < 10K
3.0
10K R < 100K
10.0
100K R < 1M
25.0
1M R < 10M
30.0
Range(
) ppm/
1≤ R<10 ±
500
10 ≤ R < 1M
±
200
0 603 :
±
250
1M ≤ R < 10M ±
300
RR
RTT
×
×
0
00
6
1
10