User's Manual
Chapter 3 Connecting Cables
RFD01F Series Installation Manual v1.0 46
©Samsung Proprietary and Confidential
Ground Cable Connection
To connect the ground cable
1 Make sure that operator has the following items:
Table 18. Parts and Tools for Grounding
Category
Description
Installation
Section
RRU Grounding Terminal~TGB
Cable
F-GV AWG8× 1C
Heat Shrink Tube
(Spec/Color/Lengt
h)
Ф 0.39 in.(10 mm)/ Green/1.96 in.(50 mm)
Pressure Terminal
TGB
Check TGB specifications per site and prepare pressure
terminals.
RRU
AWG8, 2 Hole, Hole Diameter: 1/4 in.(6.3 mm), Hole Distance:
0.63 in.(16 mm)
Fastener
TGB
Check TGB specifications per site and prepare connecting parts.
RRU
M6 × 12L SEMS/2 EA
Recommended
Torque Value
M6 SEMS
43 lbf·in
Working Tools
Torque Driver((10~50 lbf·in)), Screw Driver Bit('+', No.3),
Cable Cutter(0.23~1.25 in.(6~32 mm)), Crimping Tool(1.5~16 mm2), Cable
Stripper(0.15~0.62 in.(4~16 mm)),Heating Gun, Nipper, Screw Driver('+', No.3)
For the pressure terminal or the cable, the UL Listed products or equivalent should be used.
Ex) Manufacturer-Panduit
RRU: AWG8 Pressure Terminal(LCD8-14A-L)