2 Install a ground cable from the MGB to the RRU ground terminal.
Figure 50. Connecting Ground Cable (1)
3 Assemble a pressure terminal and a heat shrink tube at the end of the RRU
ground cable.
4 Align the pressure terminal to the mounting hole of the RRU ground terminal.
5 Firmly fix the pressure terminal onto the RRU ground terminal using fasteners.
Figure 51. Connecting Ground Cable (2)
Ground Cable
Heat Shrink Tube (Clear)
Pressure Terminal
M6 SEMS (Hex. +)
[Bottom View]
MGB
Ground Cable
Front