User's Manual
Chapter 3 Connecting Cables
RFD01P Series Installation Manual v1.0 lxx
Copyright © 2017, All Rights Reserved.
Connecting CPRI Cable
The method for configuring the CPRI cable’s cascade is sorted into connection-
oriented and end-oriented.
Cascade can be connected up to maximum three systems.
Figure 59. The method for configuring the CPRI Cable’s cascade
To connect CPRI Cable (Cascade connection-oriented)
1 Make sure you have the following items:
Table 29. Parts and Tools for connecting CPRI Cable_Cascade connection-oriented
Category
Description
Installation
Section
OFD(CDU Port) ~ RRU-0_L0 Port
RRU-1_L0 Port ~ RRU-0_L1 Port
Cable
CPRI Cable (Optical, Single Mode, for Outdoor Type)
Connector
OFD(CDU Port)
DLC/UPC
RRU_L0, L1 Port
JONHON, Push Pull Type, PDLC03T03(DLC/UPC)
Working Tools
Optical Connector Cleaner
In the system, the laser beam light runs through the optical cable.
The exposure of the laser beam on worker’s eye may cause serious injury so that it
should be handled with care.
RRU-0
(connection-oriented)
OFD
(CDU Port)
L0
Port
L0
Port
L0
Port
L1
Port
L1
Port