Chapter 3 Connecting Cables
Samsung 5G Station Outdoor Installation Manual v1.0 38
Copyright © 2020, All Rights Reserved
Grounding
Grounding is the process of operating an electronic system such as power supply
system, communication system, and control system, stably without damage from
lightning, transient-current, transient-voltage, and electric noise. Grounding also
helps in preventing injury from electric shock.
Ground equipment minimizes the electrical potential of the electronic device to
that of the ground, which is zero electrical potential. This prevents electrification
of the electronic device.
Connect the ground cable first. In cabling, the connection of cables without the
connection to the ground cable may cause damage of the equipment or bodily
injury to personnel.
The purposes of the ground construction are as follows:
• To prevent human life and the system from over-current, over-voltage, and
lightning
• To provide a discharge path for surge voltage generated by lightning and
power switch
• To protect the system from static electricity
• To eliminate or minimize the high-frequency potential in the system housing
• To provide a conductor for the balance and stability of high-frequency current
• To stabilize the potential of the circuit against the ground
Connecting Ground Cable (Option)
When connecting the ground cables, connect the ground cable first for before
installing system to prevent errors.
To connect a ground cable
1 Ensure that the items mentioned in below table are available.
Table 14. Parts and Tools for Connecting Ground Cable to the CPE Outdoor
Category
Description
Installation Section MGB-CPE Outdoor Ground Terminal
Cable 14 AWG × 1C
Bending Radius 8 × OD
Heat Shrink Tube
(Spec/Color/Length)
Ф 0.4 in. (10 mm)/Clear/2 in. (50 mm)
Pressure Terminal MGB Checking MGB specifications per site and preparing connecting parts
CPE
Outdoor
14 AWG, 2 Hole, Hole diameter: 1/4 in. (6.4 mm), Hole spacing: 0.63 in.
(16 mm)