User's Manual
Mobile WiMAX Indoor RAS SPI-2210 System Description/Ed.07
© SAMSUNG Electronics Co., Ltd. 3-10
3.2.3 PDP-PIR
PDP-PIR is mounted on the top of the indoor SPI-2210.
Figure 3.4 PDP-PIR Configuration
Board Name Quantity Function
PDP-PIR 1 Power Distribution Panel-Premium Indoor Redundancy
PDP-PIR receives DC power via a rectifier and distributes it to
each block in a rack.
MRU-2/MRR on the RFB, AICU, Fan Control Module and auxiliary device part receive
-48 VDC from the PDP-PIR and the FCM branches the supplied power to four fans in the
indoor SPI-2210. The PDP-PIR supplies the power to each board of DMB via MBB-P and
each board uses -48 VDC supplied after converting into the required power for the
corresponding board.
Antenna Interface Control Unit (AICU)
The AICU is the unit to supply the power and to receive/transmit alarm/control
message to TTLNA (service provider’s optional device). For more detailed
information, refer to section ‘5.1’.
PDP-PIR