User's Manual
Mobile WiMAX Indoor RAS SPI-2210 System Description/Ed.07
© SAMSUNG Electronics Co., Ltd. 3-13
The indoor SPI-2210 keeps the internal temperature of the rack to ensure the normal
operation of the system as shown in the figure below:
Figure 3.7 Radiation Structure of Indoor SPI-2210
The FCM as a fan controller of the indoor SPI-2210 detects the internal temperature of the
system via the temperature sensor attached inside the system and controls the speed of the
fan rotation. The FCM collects the fan status as Open (fault)/Close (Normal) and reports to
the upper layer.
DMB cooling fan (FAN-PID) and RFB cooling fans (FAN-PIR) controlled by the FCM
operates in low speed when the system internal temperature is low and in high speed when
high.
Hot Air Exhaust
Cool Air Intake
Dust Filter
Top Space
FAN
MRU
Air Baffle
MCU
MRU
Air Baffle
AICU
DMB Cooling Fan
MRU-2 Cooling Fan
DMB
Air Baffle
FAN