Loading Message Flow
After performing the pre-loading procedure, if the method of loading is determined, the
Main OAM (ULM) of the MMA-S which performs the operation and the maintenance of
the entire Outdoor SPI-2210 performs loading by using the SFTP to the corresponding IS
(remote IS or its own storage). Then, the Main OAM (ULM) becomes the internal image
server for the lower board and performs the loading procedure.
The information on the software loaded in the outdoor SPI-2210 can be checked in the
upper management system.
The loading message flow is as the following figure:
Figure 4.19 Loading Message Flow
Outdoor SPI-2210
MRA-S
MMA-S
Outdoor SPI-2210
MRA-S
MMA-S
• • • •
WSM(RS/IS)
Registration
Image Loading
RS/IS
Registration
Image Loading
RS/IS
Non-volatile
Storage
Non-volatile
Storage