User's Manual

Mobile WiMAX Outdoor RAS SPI-2210 System Description/Ed.05
© SAMSUNG Electronics Co., Ltd. 2-15
Cabinet Weight (kg) About 410 or less
Environmental Condition
The table below lists the environmental conditions and related standards such as
operational temperature and humidity.
Category Range Applied Standard
Temperature Condition
a)
-40~50°C (-40~122°F) GR-487-CORE Sec. 3.26
Humidity Condition
a)
5~95%
However, the vapor content for air
of 1 kg should not exceed 0.024 kg.
GR-487-CORE Sec.3.34.2
Altitude -60~1,800 m (-197~6,000 ft) GR-63-CORE Sec.4.1.3
Earthquake Zone 4 GR-63-CORE Sec.4.4.1
Vibration Commercial Transportation Curve 2 GR-63-CORE Sec.4.4.4
Noise
(sound pressure level)
Under 65 dBA in distance of 1.5 m
(5 ft) and height of 1.0 m (3 ft).
GR-487-CORE Sec.3.29
Electromagnetic Wave
(EMI)
Standard satisfied FCC Title47 Part 15 Class B
GR-1089-CORE Sec. 3.2
US Federal Regulation Standard satisfied FCC Title47 Part27
a) The standards of temperature/humidity conditions are based on the value on the position where is 400 mm
(15.8 in.) away from the front of the system and in the height of 1.5 m (59 in.) on the bottom.
Environmental Alarm
The table below lists the environmental alarm provided in the outdoor SPI-2210 in default.
For the details on the environmental alarm, refer to the specific items.
Category Description
UCM Status Universal Control Module (UCM) Fail Report
Temperature Alarm
High Temperature
Fan Fail - DMB (Digital Main Block) Fan Fail
- RFB (RF Block) Fan Fail
Others
Flood, Fire, Door open, etc.
Details