User's Manual

Mobile WiMAX Outdoor RAS SPI-2210 System Description/Ed.05
© SAMSUNG Electronics Co., Ltd. 3-13
(Continued)
Board Name Quantity Function
HDM-D 1 Heater and Damper Module-DMB
- HDM-D raise the temperature inside the system. (Heater: 1EA)
- Open/close the exhauster of cabinet in the back of DMB
Membrane Filter 2 Protect the outdoor SPI-2210 from dust and rain
Membrane filter
The membrane filter enables the cool air to flow into the outdoor SPI-2210 and to
protect the outdoor SPI-2210 from dust and rain.
HDM-R/HDM-D
The HDM consists of the heater and damper. On the outdoor SPI-2210, HDM-R
mounted on the bottom of the RFB and HDM-D mounted on the bottom of DMB are
mounted.
The function of damper and heater is as follows:
Damper
If the outdoor SPI-2210 is in the cold start or low temperature mode, the damper
blocks the ventilating opening of the cabinet to prevent the outdoor SPI-2210 from
heat loss in case of internal heating and to circulate the air in the inside.
Cold Start & low temperature mode: Damper Close
Normal temperature & high temperature mode: Damper Open
Heater
The heater enables to raise the temperature inside the system when the temperature
inside the system becomes the permissible level or less when initializing the
system, operating the system. The heater is installed in the DMB and in the RFB,
respectively, in order that the DMB and the RFB can operate normally when the
system is in the low temperature.
The UCM operates the heater according to the temperature inside the system
detected by the temperature sensor mounted inside the outdoor SPI-2210.
Cold Start & low temperature mode: Operating the heater
Normal temperature & high temperature mode: Stopping the heater
Fan
On the outdoor SPI-2210, the fan (FAN-POD) dedicated for the DMB, which
consists of a set of two fans is mounted, and three fans (FAN-POR) dedicated for RFB
are mounted. The FAN-POD and the FAN-POR maintain the temperature inside the
cabinet appropriately in order that the system can operate normally. The UCM controls
the fan according to the temperature inside the system detected by the temperature
sensor mounted inside the outdoor SPI-2210.
Cold Start & low temperature mode: Operating at low speed