DACS Operation
If the temperature inside the outdoor SPI-2210 becomes the permissible level or less, the
DACS operates the damper of HDM as the closed loop mode to circulate the air inside the
system, and maintains the appropriate temperature inside the system by using the
generation of heat of the system or the heater.
To the contrary, if the temperature inside the outdoor SPI-2210 becomes the permissible
level or more, the DACS operates the damper of HDM as the open loop mode. The open
loop mode enables the cool air outside the system to flow into the inside of the system and
cool the module inside the system, and it also enables the hot air inside the system to be
released out of the system and cool the system.
Fan Operation
If the temperature inside the outdoor SPI-2210 is low, FAN-POD and FAN-POR operate at
low speed by the control of UCM. To the contrary, if the temperature inside the outdoor
SPI-2210 is high, FAN-POD and FAN-POR operate at high speed by the control of UCM.