User's Manual
Mobile WiMAX RAS SPI-2213 System Description
© SAMSUNG Electronics Co., Ltd. 5-1
CHAPTER 5. Additional Functions
and Tools
5.1 RET
The SPI-2213 can support the RET function by connecting an antenna with an AISG 2.0
interface and an RRH with an AISG 2.0 interface.
To provide the RET function, the SPI-2213 sends and receives control messages to and from
the WSM through the RET controller within the RRH (AISG2.0 interface), MRA-F (Digital
I/Q and C & M: Optic) and RET controller of MMA-G. By using this path, the WSM can
carry out the RET function that controls the antenna tilting angle remotely.
In addition, for the RET operation, the RRH provides power to every antenna connected to it.
Figure 5.1 RET Interface
DU
MMA-G
WSM
(SNMP Manager)
MRA-F #0
MRA-F #1
MRA-F #5
.
.
.
RET Relay
RRH#0
RRH#1
RRH#2
Digital I/Q
and C & M
Antenna (RET Motor)
Antenna (RET Motor)
Antenna (RET Motor)
Antenna (RET Motor)
Antenna (RET Motor)
Antenna (RET Motor)
A
ntenna (AISG interface)
RS-485
and
Power
SPI-2213
RET Relay
RET Relay
RET
Controlle
r