User's Manual

CHAPTER 3. SPI-2213 Architecture
3-34
© SAMSUNG Electronics Co., Ltd.
3.3.3.11 Common Event Router (OER)/Common Event Viewer (OEV)
The OER/OEV manages the event history as the text format. The OER/OEV transmits the
information on all the events received from the OAM applications to the related agent
(OAGS, WebEMT), and creates and saves the history file of the daily/hourly events, and
displays the log contents on the operator window (IMISH) in real time.
OER Major Functions
y Event transmission
OER/OEV transmits the information on the generated event to the OAGS or the
WebEMT block, thus it enables to report it to the management system.
y Creating and saving the event history file
OER/OEV creates and saves the daily/hourly event history file in its own nonvolatile
storage as the 1 Mbyte maximum size.
y Event display
OER/OEV displays the event generated in the SPI-2213 on the operator window
(IMISH) in real time.
OER/OEV Implementation
OER/OEV is implemented on the MMA-G as shown in the figure below.
Figure 3.26 OER/OEV Block
MRA-F #5
MRA-F #4
MRA-F #3
MRA-F #2
MRA-F #1
MRA-F #0
MMA-G
MEI-B