3.3.3.9 Common Performance Management (OPM)
OPM collects and provides the performance data for the upper management system operator
to know the SPI-2213 performance. The OPM collects the event generated during the
system operation and the performance data and transmits them to the management system.
The collection cycle of the statistics data of the actual OPM can be set as 15 minutes,
30 minutes, 60 minutes, and if the entire statistics file of the binary format is created every
15 minutes, the management system collects it periodically via the FTP/SFTP.
OPM Main Functions
y Record and collect statistics data
Record statistics data to the memory and generate the statistics file by regularly
collecting data per each board
y Save the statistics data
Save the statistics data of each board in its own nonvolatile storage during up to eight
hours
y Inquire and change the statistics configuration information
Inquire and change the collection cycle (BI) and the threshold of the statistics data
y Threshold Cross Alert (TCA)
Generate the TCA (Critical, Major, Minor) according to the defined threshold in every
collection cycle and report it to the UFM
y Monitor the statistics in real time
Provide the real-time monitoring function for the specific statistics item designated by
the operator
OPM Implementation
OPM is implemented on the MMA-G and all lower board as shown below.
Figure 3.22 OPM Block
MRA-F #5
MRA-F #4
MRA-F #3
MRA-F #2
MRA-F #1
MRA-F #0
MMA-G
MEI-B