User Manual

CDMA PicoBTSTM Hardware Description Page 23
If the PicoBTS
TM
base station is installed in accordance with
the clearances prescribed for installation, the PicoBTS
TM
base
station allows easy access to the faulty module for
replacement. The PicoBTS
TM
base station is designed to
minimize the number of steps required to remove and replace a
module.
4.3.3 Mean time to repair (MTTR)
MTTR applies to the length of time required to replace a FRU)
and includes the following operations by field personnel:
Time required to perform fault detection and isolate the
problem to a single FRU
Time required to disassemble mounting fixtures (if any)
Time required to replace the failed FRU
Time required to reassemble mounting fixtures
Time required to align and check out of the replacement FRU.
At the site level, the PicoBTS
TM
base station has a MTTR of
thirty (30) minutes or less, and a maximum time to repair
(MTTR
MAX
) of ninety (90) minutes or less at the 95
th
percentile.
Note: MTTR and MTTR
MAX
do not include the time required to
travel to the PicoBTS
TM