Important information regulation regarding the refrigerant used
This product contains uorinated greenhouse gases. Hermetically sealed system. Do not vent gases into the atmosphere.
t Inform user if system contains 5 tCOe or more of uorinated greenhouse gases. In this case, it has to be checked
for leakage at least once every 12 months, according to regulation n°517/2014. This activity has to be covered by
qualied personnel only.
t In case situation above (5 tCOe or more of R-410A), installer (or recognised person which has responsability for
nal check) has to provide a maintenance book, with all the information recorded according to REGULATION(EU)
N° 517/2014 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 16 April 2014 on uorinated greenhouse
gases.
CAUTION
Please ll in the following with indelible ink on the refrigerant charge label
supplied with this product and on this manual.
f : The factory refrigerant charge of the product.
f : The additional refrigerant amount charged in the eld.
f + The total refrigerant charge.
a. Factory refrigerant charge of the product: see unit name plate
b. Additional refrigerant amount charged in the eld(Refer to the
above information for the quantity of refrigerant replenishment.)
c. Total refrigerant charge
d. Refrigerant cylinder and manifold for charging
NOTE
The lled-out label must be adhered in the proximity of the product charging
port (e.g. onto the inside of the stop valve cover).
Unit kg tCOe
①, a
②, b
+, c
Refrigerant type GWP value
R-410A 2088
GWP=Global Warming Potential
Calculating tCOe : kg x GWP /
1000
Indoor unit
Outdoor unit
d
Pressure table for temperatures
If you need extra refrigerant charging due to leakage or relocating the product, refer to below table before charging
refrigerant.
f AC071JXSCEH/EU
Cooling operation Unit : [kPa, G]
Indoor Temp.(°C)
(Dry-Bulb/Wet Bulb)
Outdoor Temp.(°C)
32/23 27/19 21/15
50 1134 1020 916
35 1040 944 777
21 999 896 802
7 1020 912 808
-18 1008 874 766