Field Setting Value (FSV) Table
Reset the power after changing the Field Setting Value.
•Code10:Upperandlowertemperaturelimitsofeachoperationmodeofwiredremotecontroller
Heating(Water Out, Room), Cooling(Water Out, Room), DHW(Tank)
•Code20:WaterlawdesignandexternalroomthermostatHeating(2WLsforfloor&FCU),
Cooling(2 WLs for floor & FCU), WL & Thermostat types
FieldSettingValue
Main Menu &
Code
Sub Menu Function Description Sub Code Default Min Max Step Unit
Remote
Controller
Setting Range
Code 10
Water Out Temp for Cooling
Max 11
25 18 25 1 ˚C
Min 12
16 5 18 1 ˚C
Room Temp for Cooling
Max 21
30 24 30 1 ˚C
Min 22
18 18 22 1 ˚C
Water Out Temp for Heating
Max 31
55 37 55 1 ˚C
Min 32
25 15 37 1 ˚C
Room Temp for heating
Max 41
30 24 30 1 ˚C
Min 42
16 16 22 1 ˚C
DHW Tank Temp
Max 51
50 50 70 1 ˚C
Min 52
40 30 40 1 ˚C
Back light timer
Time 61
5 0 30 1 sec
Water Law
Code 20
Outdoor Temp for Water Law
(Heating)
Point
11
-10 -20 5 1 ˚C
Point
12
15 10 20 1 ˚C
Water Out Temp for WL1
Heating (WL1-Floor)
Point
21
40 17 55 1 ˚C
Point
22
25 17 55 1 ˚C
Water Out Temp for WL2
Heating (WL2-Fan Coil Unit)
Point
31
50 17 55 1 ˚C
Point
32
35 17 55 1 ˚C
Heating Water Law for Auto
Mode
WL Type 41
1(WL1) 1 2(WL2) - -
Outdoor Temp for Water Law
(Cooling)
Point
51
30 25 35 1 ˚C
Point
52 40
35 45 1 ˚C
Water Out Temp for WL1
Cooling (WL1-Floor)
Point
61 25
18 25 1 ˚C
Point
62 18
5 18 1 ˚C
Water Out Temp for WL2
Cooling (WL2-Fan Coil Unit)
Point
71 18
18 25 1 ˚C
Point
72 5
5 18 1 ˚C
Cooling Water Law
WL Type 81
1(WL1) 1 2(WL2) - -
External Thermostat Application
#1(Floor) 91 0(No)
0 1(Yes) - -
#2(FCU) 92 0(No)
0 1(Yes) - -